NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-01-328-5365 Item Description: Resistor Variable N | 5905 | 013285365 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
3299p-Dm3-203 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAPN | SECTION QUANTITY | 1 |
AAQL | BODY STYLE | RECTANGULAR |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 0.180 INCHES NOMINAL |
ABWV | SHAFT DIAMETER | 0.090 INCHES NOMINAL |
ABXF | SHAFT LENGTH | 0.045 INCHES MINIMUM AND 0.075 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.395 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0.395 INCHES MAXIMUM |
AEDX | SHAFT STYLE | ROUND, SLOTTED |
AEFD | ACTUATOR TYPE | SINGLE SHAFT |
AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 9000.0 NOMINAL |
AEFL | MAXIMUM RUNNING TORQUE | 5.00 INCH-OUNCES |
AFJN | III FRAGILITY FACTOR | MODERATELY RUGGED |
APXH | TERMINAL LOCATION | RIGHT ADJACENT SIDE TWO ROWS |
AXGY | MOUNTING METHOD | TERMINAL |
CBME | III CUBIC MEASURE | 0.038 CUBIC INCHES |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 20.0 KILOHMS SINGLE SECTION |
CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 9000.0 NOMINAL |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.100 INCHES NOMINAL |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -100.0 TO 100.0 SINGLE SECTION |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.5 FREE AIR SINGLE SECTION |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -10.0 TO 10.0 SINGLE SECTION |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | CLUTCH |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 70.0 SINGLE SECTION |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |
ADAU | BODY HEIGHT | 0.245 INCHES MAXIMUM |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.200 INCHES NOMINAL |
AEFK | MAXIMUM STARTING TORQUE | 5.00 INCH-OUNCES |
AYQR | CENTER TO CENTER DISTANCE BETWEEN TERMINAL ROWS | 0.100 INCHES NOMINAL |
FEAT | SPECIAL FEATURES | IMMERSION SEALED |
329-003 | 329-0001-002 | 329-0048 | 329-000-000L005 |
329-001-007 | 329-0002 | 329-0000 | 329-002 |
329-001 | 329-0001 | 329-00018 | 329-002 |
329-0048 | 329-004-00A | 329-009 | 329-001 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote