NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-377-2285 Item Description: Circuit Breaker | 5925 | 013772285 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Mm2r-D3-Lc07d-Nu-15-2 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
THSD | THREAD SERIES DESIGNATOR | UNC |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 135.0 ALL LOCATIONS |
ADAQ | BODY LENGTH | 2.500 INCHES NOMINAL |
CPRQ | RESET METHOD | MANUAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.062 INCHES NOMINAL |
AKPX | POLE QUANTITY | 2 |
CMLP | THREAD QUANTITY PER INCH | 32 |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.750 INCHES NOMINAL |
ADTV | CASE MATERIAL | PLASTIC |
AGAV | III END ITEM IDENTIFICATION | PANEL, AC DISTB., P/N 2009-002-01 USED ONBOARD 47 FT MLB COAST GUARD VESSELS |
ADAT | BODY WIDTH | 1.500 INCHES NOMINAL |
SR-5 | MANUFACTURERS CODE | 1Y502 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 15.0 AMPERES AC AND 15.0 AMPERES DC ALL LOCATIONS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
SR-5 | DESIGN CONTROL REFERENCE | MM2R-D3-LC07D-A-15-2 |
AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.938 INCHES NOMINAL |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC AND 65.0 DC ALL LOCATIONS |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
TTQY | TERMINAL TYPE AND QUANTITY | 4 THREADED STUD |
SR-5 | THE MANUFACTURERS DATA | |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.481 INCHES NOMINAL |
CPRW | ACTUATOR FUNCTION | RESET |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC AND 5000.0 DC ALL LOCATIONS |
AJEC | BOSS HEIGHT | 0.140 INCHES NOMINAL |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONS |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 1.938 INCHES NOMINAL |