5962-01-094-3128 Item Description: Microcircuit Linear | 5962 | 010943128 | 0 | N | B | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | B | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
23-00515-1 | 1 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
ADAR | BODY OUTSIDE DIAMETER | 0.335 INCHES MINIMUM AND 0.370 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0.165 INCHES MINIMUM AND 0.185 INCHES MAXIMUM |
AEHX | MAXIMUM POWER DISSIPATION RATING | 650.0 MILLIWATTS |
AFGA | OPERATING TEMP RANGE | -55.0/+125.0 DEG CELSIUS |
AFJQ | STORAGE TEMP RANGE | -65.0/+150.0 DEG CELSIUS |
CBBL | FEATURES PROVIDED | BIPOLAR AND MONOLITHIC AND HIGH VOLTAGE AND W/STROBE |
CQSJ | INCLOSURE MATERIAL | METAL |
CQSZ | INCLOSURE CONFIGURATION | CAN |
CQZP | INPUT CIRCUIT PATTERN | 2 INPUT |
CSSL | DESIGN FUNCTION AND QUANTITY | 1 AMPLIFIER, OPERATIONAL, GENERAL PURPOSE |
CTFT | CASE OUTLINE SOURCE AND DESIGNATOR | MO-002-AL JOINT ELECTRON DEVICE ENGINEERING COUNCIL |
CWSG | TERMINAL SURFACE TREATMENT | TIN |
TEST | TEST DATA DOCUMENT | 96906-MIL-S-883B STANDARD (INCLUDES INDUSTRY OR ASSOCIATION STANDARDS, INDIVIDUAL MANUFACTUREER STANDARDS, ETC.). |