Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-01-467-5915 Item Description: SWITCH,ROTARY | 5930 | 014675915 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
FE640-3000-806N | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AFBH | INDIVIDUAL SECTION QUANTITY | 5 |
AASA | THREAD LENGTH | 0.417 INCHES MINIMUM AND 0.457 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
AJZE | SWITCH CONTACT BASIC DESIGN | NONPILE-UP SYMMETRICAL |
THSD | THREAD SERIES DESIGNATOR | UNEF SINGLE MOUNTING FACILITY |
CQMK | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL 28.0 AC AT ALTITUDE |
CQJX | NOMINAL THREAD SIZE | 0.375 INCHES SINGLE MOUNTING FACILITY |
ADAV | OVERALL DIAMETER | 1.152 INCHES MINIMUM AND 1.172 INCHES MAXIMUM |
AXGY | MOUNTING METHOD | THREADED BUSHING SINGLE MOUNTING FACILITY |
AKPX | POLE QUANTITY | 2 EACH SECTION FRONT |
STYL | STYLE DESIGNATOR | TAP, CIRCULAR, BUSHING MOUNT |
ABHP | OVERALL LENGTH | 2.389 INCHES MINIMUM AND 2.455 INCHES MAXIMUM |
AKPY | THROW QUANTITY | 6 EACH SECTION FRONT |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
CTHF | CONTACT LOAD CURRENT RATING | 75.0 MILLIAMPERES RESISTIVE LOAD AC AT SEA LEVEL 250.0 MILLIAMPERES RESISTIVE LOAD AND 100.0 MILLIAMPERES INDUCTIVE LOAD DC AT SEA LEVEL |
AAJD | THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
CSCF | TERMINAL TYPE | TAB, SOLDER LUG |
CRJH | SWITCH ACTUATOR INDEXING POSITION QUANTITY | 6 SINGLE ACTUATOR |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote