Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5999-00-665-2098 Item Description: Delay Line | 5999 | 006652098 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
B7408046-2rev4 | 6 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | RECTANGULAR, BRACKETED |
AAUB | HOLE DIAMETER | 0.156 INCHES NOMINAL |
ABHP | OVERALL LENGTH | 1.750 INCHES NOMINAL |
ADAQ | BODY LENGTH | 1.000 INCHES NOMINAL |
ADAT | BODY WIDTH | 6.000 INCHES NOMINAL |
AFBH | INDIVIDUAL SECTION QUANTITY | 1 |
AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 4.500 INCHES NOMINAL |
AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 1.500 INCHES NOMINAL |
AFGA | OPERATING TEMP RANGE | -40.0 TO 75.0 DEG CELSIUS |
AKPV | MOUNTING FACILITY QUANTITY | 4 |
ANNQ | MATERIAL AND LOCATION | ANY ACCEPTABLE OVERALL |
ANNR | SURFACE TREATMENT AND LOCATION | ENAMEL, DULL GRAY, METALLIC CASE |
ANSL | INPUT IMPEDANCE RATING | 150.000 OHMS |
ANSR | OUTPUT IMPEDANCE RATING | 150.000 OHMS |
ARBR | BODY DEPTH | 6.563 INCHES NOMINAL |
AZGM | MOUNTING FACILITY | UNTHREADED HOLE |
BBBW | MOUNTING PROVISION ARRANGEMENT STYLE | FOUR POSITION RECTANGULAR |
BZWM | SIGNAL DELAY METHOD | INDUCTANCE |
CCDN | DELAY TIME VARIATION METHOD | TAPPED |
CCDQ | SECTION DELAY TIME | 8.000 MICROSECONDS NOMINAL SINGLE SECTION |
CCDR | SEGMENT QUANTITY PER SECTION | 3 SINGLE SECTION |
CCDS | SEGMENT DELAY TIME | 2.000 MICROSECONDS NOMINAL SINGLE SECTION 2ND SEGMENT |
CCDS | SEGMENT DELAY TIME | 3.000 MICROSECONDS NOMINAL SINGLE SECTION 1ST SEGMENT |
CCDS | SEGMENT DELAY TIME | 3.000 MICROSECONDS NOMINAL SINGLE SECTION 3RD SEGMENT |
CCFF | TERMINAL TYPE AND QUANTITY | 6 TAB SOLDER LUG |
TEST | TEST DATA DOCUMENT | 24446-7408046 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW |
ZZZV | FSC APPLICATION DATA | RADAR NONAIRBORNE EXCEPT FIRE CONTROL AND GUIDED MISSILE |
B74.12 | B74.1 | B74.12 | B74-1-4 |
B74.12 | B74.1 | B74.12 | B74.1 |
B74.1 | B74.12 | B74.12 | B74.1 |
B74.12 | B74.12 | B74.12 | B74-1-4 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote