5940-00-170-9642 Item Description: Terminal Board | 5940 | 001709642 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
2-150 | 2 | 1 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAMA | MOUNTING HOLE DIAMETER | 0.165 INCHES |
AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 1700.0 |
AAQL | BODY STYLE | BARRIER TYPE |
ABCS | TERMINAL ROW QUANTITY | 2 |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.688 INCHES |
ABCU | DISTANCE BETWEEN TERMINAL ROW CENTERS | 0.625 INCHES |
ABCX | BOARD CONSTRUCTION | HOLLOW CONSTRUCTION WITHOUT INSULATED STRIP |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.062 INCHES |
ABDV | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.625 INCHES |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.594 INCHES |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.219 INCHES |
ABGN | BOARD OVERALL LENGTH | 2.500 INCHES |
ABGP | BOARD OVERALL WIDTH | 1.812 INCHES |
ABGQ | BOARD OVERALL HEIGHT | 0.750 INCHES |
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 0.750 INCHES |
ABGS | BASE THICKNESS | 0.438 INCHES |
AMPS | CURRENT RATING IN AMPS | 50.0 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
CQCZ | TERMINAL CONNECTING LINK QUANTITY | 2 SINGLE |
CRNL | NONFEEDTHRU TERMINAL TYPE | 857 SINGLE |
CSCR | TERMINAL CONNECTING LINK TYPE | 1 SINGLE |
CSCS | NONFEEDTHRU TERMINAL QUANTITY | 2 SINGLE |
CWLG | TERMINAL PATTERN ARRANGEMENT | MULTI-ROW |
CWLN | TERMINAL DESIGN | LINKED NONFEEDTHRU |
MATT | MATERIAL | COPPER ALLOY TERMINALS |
MATT | MATERIAL | PLASTIC PHENOLIC BOARD |
SFTT | SURFACE TREATMENT | NICKEL TERMINALS |
2-1-090-1160 | 2-1-090-1132 | 2.1 1-2 | 2-1-090-1152 |
2 1-1 2X1-1 2 | 2-1-090-1005 | 2-1-090-1152 | 2 1-1 2X1-1 2 |
2-1-090-1153 | 2-1-090-1005 | 2-1-096 | 2 1-1 2X1-1 2 |
2-1-101 | 2 1 1 16X2 1 8IN BORES | 2-1-0-1H | 2-1-1 2ZC2 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote