Note : We Will Not Share Your Information To Any Third Parties.
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 10.250 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 2.950 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 4.000 INCHES NOMINAL |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | SINGLE 1ST OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 2ND OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 125.0 AC POUNDS PER HOUR WET 2ND OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 230.0 AC POUNDS PER HOUR WET 1ST OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | -15.0 DC VOLTS MINIMUM 3RD POWER OUTPUT AND -12.0 DC VOLTS MAXIMUM 3RD POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 12.0 DC VOLTS MINIMUM 1ST POWER OUTPUT AND 15.0 DC VOLTS MAXIMUM 1ST POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 5.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 1ST OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 1ST OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 2ND OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 2ND OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | +0.1/+71.0 DEG CELSIUS |
BGHX | OUTPUT CONTROL QUANTITY | 1 1ST POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 1 2ND POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 1 3RD POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 1ST POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 2ND POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 3RD POWER OUTPUT |
CBBL | FEATURES PROVIDED | FILTER |
CWGH | OUTPUT CURRENT RATING | 1.0 DC AMPERES NOMINAL 2ND POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 800.0 DC MILLIAMPERES MINIMUM 1ST POWER OUTPUT AND 1.0 DC AMPERES MAXIMUM 1ST POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 800.0 DC MILLIAMPERES MINIMUM 3RD POWER OUTPUT AND 1.0 DC AMPERES MAXIMUM 3RD POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | FRONT PANEL 1ST POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | FRONT PANEL 2ND POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | FRONT PANEL 3RD POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 4 1ST POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 4 2ND POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 4 3RD POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 1ST POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 2ND POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 3RD POWER OUTPUT |
CWHQ | INPUT CONNECTION TYPE | TERMINAL STRIP 1ST OPERATING POWER RQMT |
CWHQ | INPUT CONNECTION TYPE | TERMINAL STRIP 2ND OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 2 1ST OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 2 2ND OPERATING POWER RQMT |
BAA-139-3 | BAA-350A | BAA-58-05 | BAA-58-04 |
BAA-0096 | BAA008 | BAA0017AC3-4C23 | BAA-0201 |
BAA-0096 | BAA-58-01 | BAA-0137B | BAA-0195C |
BAA-139-3 | BAA-0169 | BAA0017AC3-4C23 | BAA-58-03 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote