Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-00-449-5248 Item Description: Power Supply | 6130 | 004495248 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
28 824206 1 | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 3.500 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 1.500 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 2.500 INCHES NOMINAL |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 104.0 AC VOLTS MINIMUM SINGLE OPERATING POWER RQMT AND 127.0 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | -11.8 DC VOLTS MINIMUM 2ND POWER OUTPUT AND -12.2 DC VOLTS MAXIMUM 2ND POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 11.8 DC VOLTS MINIMUM 1ST POWER OUTPUT AND 12.2 DC VOLTS MAXIMUM 1ST POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 400.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | -25.0/+71.0 DEG CELSIUS |
BGHX | OUTPUT CONTROL QUANTITY | 1 1ST POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 1 2ND POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | FIXED VOLTAGE 1ST POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | FIXED VOLTAGE 2ND POWER OUTPUT |
BHQN | RECTIFICATION METHOD | SINGLE PHASE FULL WAVE CENTER TAP |
CBBL | FEATURES PROVIDED | FILTER |
CWGH | OUTPUT CURRENT RATING | -120.0 DC MILLIAMPERES NOMINAL 2ND POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 120.0 DC MILLIAMPERES NOMINAL 1ST POWER OUTPUT |
CWGZ | RIPPLE VOLTAGE AT FULL LOAD | 0.5 MILLIVOLTS RMS 1ST POWER OUTPUT |
CWGZ | RIPPLE VOLTAGE AT FULL LOAD | 0.5 MILLIVOLTS RMS 2ND POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | FRONT PANEL 1ST POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | FRONT PANEL 2ND POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 1ST POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 2ND POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 1ST POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 2ND POWER OUTPUT |
28-00003-309 | 28.00-15 | 28-0000077 | 28-0000129 |
28-0-310 | 28-0-307 | 28-0-364 | 28 0 309 |
28.00.965.01 | 28.00-15 | 28-000-0004 | 28-0-309 |
28-0-310 | 28-0-345 | 28-00003-309 | 28-0-307 |