Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-00-578-9991 Item Description: Relay Electromagnet | 5945 | 005789991 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | S | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Mb4139 | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAJD | THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 1.620 INCHES NOMINAL |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.940 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 2.510 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.410 INCHES NOMINAL |
ADTV | CASE MATERIAL | METAL |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AFRG | CONTACT MATERIAL | SILVER |
AKDX | WINDING QUANTITY | 1 |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APCN | COIL QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 245.0 OHMS NOMINAL SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
APNQ | ARC QUENCHING METHOD | AIR |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 3 THREADED STUD SINGLE MOUNTING FACILITY |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CBME | III CUBIC MEASURE | 5.733 CUBIC INCHES |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | TRIANGLE SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 98.0 MILLIAMPERES DC SINGLE WINDING |
CRXH | TIME DELAY | 0.005 SECONDS NOMINAL FIXED RELEASE TIME |
CRXH | TIME DELAY | 0.025 SECONDS NOMINAL FIXED OPERATE TIME |
CSQJ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 1.190 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 24.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 60.0 AMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
FEAT | SPECIAL FEATURES | FOUR TERMINALS COMMON TO CONTACT TERMINALS |
PMLC | PRECIOUS MATERIAL AND LOCATION | CONTACTS SILVER |
PRMT | PRECIOUS MATERIAL | SILVER |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
TTQY | TERMINAL TYPE AND QUANTITY | 4 WIRE HOOK ENERGIZING ELEMENT AND CONTACTS |
MB4-052P-701 | MB4-072P(719 | MB4-040P | MB4-052P-706 |
MB4-080P-701 | MB4-052P-710 | MB4-072P | MB4-072W-700 |
MB4-060P-701 | MB4-060W-710 | MB4 064P 702 | MB4-052P-703 |
MB4-052P-702 | MB4-052P-705 | MB4-064P | MB4-040P-709 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote