Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5910-01-097-2016 Item Description: Capacitor Variable | 5910 | 010972016 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
922-0583-060 | 1 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | PISTON |
ABHP | OVERALL LENGTH | 0.500 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.281 INCHES NOMINAL |
ADAV | OVERALL DIAMETER | 0.145 INCHES NOMINAL |
AEBC | TEMP COEFFICIENT OF CAPACITANCE IN PPM PER DEG CELSIUS | 0.0 SINGLE SECTION |
AEBD | TOLERANCE OF TEMP COEFFICIENT IN PPM PER DEG CELSIUS | -50.0/+50.0 SINGLE SECTION |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.266 INCHES NOMINAL |
AECJ | QUALITY FACTOR AT 25 DEG CELSIUS | 10000.0 |
AKNA | INCLOSURE TYPE | ENCASED |
AXCM | TUNING CHARACTERISTIC | STRAIGHT LINE CAPACITY SINGLE SECTION |
AXGR | ADJUSTMENT DEVICE TORQUE | 0.300 INCH-OUNCES MINIMUM AND 3.000 INCH-OUNCES MAXIMUM |
AXGT | INSULATION DC RESISTANCE AT 25 DEG CELSIUS | 1000.0 GIGOHMS |
AXGX | INSULATION DC RESISTANCE AT MAX OPERATING TEMP | 100.0 GIGOHMS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 TERMINAL |
CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM |
CTGN | CAPACITANCE RANGE IN PICOFARADS | +0.35/+3.50 SINGLE SECTION |
CTGP | NONDERATED VOLTAGE RATING AND TYPE | 250.0 DC CONTINUOUS SINGLE SECTION |
CTGR | ADJUSTMENT DEVICE DRIVE TYPE AND QUANTITY | 1 SLOTTED SCREW |
CTGS | CAPACITANCE DRIFT IN PICOFARADS | 0.02 SINGLE SECTION |
TEST | TEST DATA DOCUMENT | 81349-MIL-C-14409 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTI |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-C-14409/14 GOVERNMENT SPECIFICATION |
922-0011-00 | 922-0020-01 | 922-0033-00 | 922-0009-00 |
922-0011-00 | 922 0007 00 | 922 0014 00 | 922 0038 00 |
922-0033-00 | 922-0036-00 | 922-0031-01 | 922-0033-00 |
922-0011-00 | 922 0028 000 | 922-0036-00 | 922-0031-001 |