5950-00-620-7844 Item Description: Transformer Power | 5950 | 006207844 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
5000550 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.740 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 3.760 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.990 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 3.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABMK | OVERALL WIDTH | 3.720 INCHES MINIMUM AND 3.780 INCHES MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.200 INCHES MINIMUM SINGLE GROUP AND 0.210 INCHES MAXIMUM SINGLE GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-DELTA AND WYE-WYE |
ADAQ | BODY LENGTH | 5.800 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 2.750 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 210.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | OPEN |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 42.0 AMPERES AC NOMINAL SINGLE COMPONENT ALL SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 195.00 AC VOLTS MINIMUM SINGLE COMPONENT SINGLE PRIMARY AND 210.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 20.70 AC VOLTS MINIMUM SINGLE COMPONENT ALL SECONDARY |
TEST | TEST DATA DOCUMENT | 97151-69C37506 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRA |
TTQY | TERMINAL TYPE AND QUANTITY | 10 WIRE LEAD |
500-0-184-10 | 500-0-160 | 500-0-184-14 | 500-0-184-14 |
500-0-184-19 | 500-0-184-19 | 500-0-184-19 | 500-0.1T |
500-0-184-14 | 500-0-184-10 | 500-0-6 | 500-0-184-19 |
500-0-300-2-1-2 | 500-0-184-14 | 500-0-134 | 500-0-134 |