Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5962-01-009-3714 Item Description: Microcircuit Linear | 5962 | 010093714 | 0 | N | B | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Q67000-A1150-F40 | 3 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ADAR | BODY OUTSIDE DIAMETER | 0.350 INCHES MINIMUM AND 0.370 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0.165 INCHES MINIMUM AND 0.185 INCHES MAXIMUM |
AEHX | MAXIMUM POWER DISSIPATION RATING | 500.0 MILLIWATTS |
AFGA | OPERATING TEMP RANGE | -55.0/+125.0 DEG CELSIUS |
AFJQ | STORAGE TEMP RANGE | -65.0/+150.0 DEG CELSIUS |
CBBL | FEATURES PROVIDED | FAST SETTLING AND HERMETICALLY SEALED AND HIGH SLEW RATE AND HIGH SPEED AND INTERNALLY COMPENSATED AND POSITIVE OUTPUTS |
CQSJ | INCLOSURE MATERIAL | GLASS AND METAL |
CQSZ | INCLOSURE CONFIGURATION | CAN |
CQZP | INPUT CIRCUIT PATTERN | 2 INPUT |
CSSL | DESIGN FUNCTION AND QUANTITY | 1 AMPLIFIER, OPERATIONAL, GENERAL PURPOSE |
CWSG | TERMINAL SURFACE TREATMENT | TIN |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote