5915-00-427-5233 Item Description: Filter Radio Freque | 5915 | 004275233 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
2892577-1 | 6 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 12.500 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 8.250 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 10.500 INCHES NOMINAL |
ADAT | BODY WIDTH | 10.000 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.319 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 11.750 INCHES NOMINAL |
AECR | VIBRATION RESISTANCE RANGE IN HERTZ | +0.0/+33.0 |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 9.000 INCHES NOMINAL |
AFGA | OPERATING TEMP RANGE | +0.0/+65.0 DEG CELSIUS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 4TH RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 5TH RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 6TH RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 1ST RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 2ND RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 3RD RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 100.0 4TH RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 100.0 5TH RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 100.0 6TH RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 75.0 1ST RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 75.0 2ND RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 75.0 3RD RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.15 VOLTS AC 4TH RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.15 VOLTS AC 5TH RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.15 VOLTS AC 6TH RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 4.4 VOLTS AC 1ST RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 4.4 VOLTS AC 2ND RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 4.4 VOLTS AC 3RD RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE |
AHCG | MAXIMUM TEMP RISE | 30.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | ENCASED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 8 UNTHREADED HOLE |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 THREADED STUD GROUND 3RD FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 6 THREADED STUD INPUT 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 6 THREADED STUD OUTPUT 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 5TH RADIO INTERFERENCE 5TH FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 6TH RADIO INTERFERENCE 6TH FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 440.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 440.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 440.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
CQRG | BODY MATERIAL | METAL |
PKWT | UNPACKAGED UNIT WEIGHT | 44.000 POUNDS |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ADJACENT SURFACES |
289-0006-00 | 289-002 | 289-002 | 289-0006-00 |
289-0001-000 | 289-0001-000 | 289-0006-000 | 289-0008-001 |
289-0006-000 | 289-0022-002 | 289-0006-00 | 289-00 |
289-0007 | 289-0008-001 | 289-0001-000 | 289-0008-001 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote