Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5915-00-078-3250 Item Description: Filter Band Pass Lo | 5915 | 000783250 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
43006010-1 | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 2.910 INCHES NOMINAL |
ADAQ | BODY LENGTH | 1.870 INCHES NOMINAL |
ADAT | BODY WIDTH | 1.560 INCHES NOMINAL |
ADAU | BODY HEIGHT | 1.870 INCHES NOMINAL |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.562 INCHES NOMINAL |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 428.0 HERTZ SINGLE BAND PASS 1ST FUNCTION |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 50.0 HERTZ SINGLE LOW PASS 2ND FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 1.2 KILOHMS SINGLE BAND PASS 1ST FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 1.2 KILOHMS SINGLE LOW PASS 2ND FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 2.4 KILOHMS SINGLE BAND PASS 1ST FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 2.4 KILOHMS SINGLE LOW PASS 2ND FUNCTION |
AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS BLANK |
AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS BLANK |
AHBL | III PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE SINGLE LOW PASS 2ND FUNCTION |
AHBL | III PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE-RESISTANCE SINGLE BAND PASS 1ST FUNCTION |
AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
AKNA | INCLOSURE TYPE | ENCASED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 3.0 SINGLE LOW PASS 2ND FUNCTION |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 6.0 SINGLE BAND PASS 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 STANDARD TUBE BASE OUTPUT 2ND FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 WIRE HOOK GROUND 3RD FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 WIRE HOOK INPUT 1ST FUNCTION |
CQFC | III SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 1.00 HERTZ SINGLE LOW PASS AND 100.00 HERTZ SINGLE LOW PASS AND 850.00 KILOHERTZ SINGLE LOW PASS AND 1.70 KILOHERTZ SINGLE LOW PASS |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
CQRG | III BODY MATERIAL | METAL |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 1.00 HERTZ SINGLE LOW PASS AND 100.00 HERTZ SINGLE LOW PASS 2ND FUNCTION |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 388.00 HERTZ SINGLE BAND PASS AND 468.00 HERTZ SINGLE BAND PASS 1ST FUNCTION |
CRBC | III DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 3.0 MAXIMUM SINGLE LOW PASS AND 3.0 MAXIMUM SINGLE LOW PASS AND 50.0 MINIMUM SINGLE LOW PASS AND 50.0 MINIMUM SINGLE LOW PASS |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
430-0-004 RE | 430-0-004 | 430-0-008 REV | 430-0-007 REV |
430-0-007 | 430-0-010 RE | 430-0-009 RE | 430-0-009 |
430-0-008 RE | 430-0-010 | 430-0-005 REV | 430-0-007 RE |
430-0-008 | 430-0-009 REV | 430-0-006 | 430-0-005 RE |