Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-01-321-1894 Item Description: Switch Thermostatic | 5930 | 013211894 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | S | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Nh2-222-3476 | 5 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | WATERTIGHT |
ABMK | OVERALL WIDTH | 2.812 INCHES NOMINAL |
ADAU | BODY HEIGHT | 2.750 INCHES NOMINAL |
AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 5.188 INCHES NOMINAL |
AFDT | SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 0.656 INCHES NOMINAL |
AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 3.281 INCHES NOMINAL |
AXGY | MOUNTING METHOD | BRACKET AND UNTHREADED HOLE |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CSCF | TERMINAL TYPE | SCREW |
CTHF | CONTACT LOAD CURRENT RATING | 16.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 2.0 AMPERES INDUCTIVE LOAD EIGHTH VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 2.5 AMPERES INDUCTIVE LOAD SEVENTH VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 8.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 9.6 AMPERES INDUCTIVE LOAD FIFTH VOLTAGE |
CTYS | CONTACT ADJUSTMENT TYPE | INTERNAL ACTUATION POINT SCREW AND INTERNAL DEACTUATION POINT SCREW |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 AC AT SEA LEVEL SECOND VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 440.0 DC AT SEA LEVEL SEVENTH VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 DC AT SEA LEVEL EIGHTH VOLTAGE |
PMLC | PRECIOUS MATERIAL AND LOCATION | CONTACTS SILVER |
STYL | III STYLE DESIGNATOR | RECTANGULAR |
ABHP | III OVERALL LENGTH | 5.188 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.281 INCHES NOMINAL |
CTHF | CONTACT LOAD CURRENT RATING | 4.0 AMPERES INDUCTIVE LOAD THIRD VOLTAGE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
CTYM | CONTACT ADJUSTMENT RANGE | +140.00/+215.00 ACTUATION POINT DEGREES FAHRENHEIT AND +140.00/+215.00 DEACTUATION POINT DEGREES FAHRENHEIT |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 440.0 AC AT SEA LEVEL THIRD VOLTAGE |
ABKW | OVERALL HEIGHT | 5.687 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | BULB |
AWTN | OPERATING TEMP RATING | 245.0 DEG FAHRENHEIT MAXIMUM |
CBBL | FEATURES PROVIDED | ELECTRICAL ACCESS PORT |
CQYJ | MOUNTING FACILITY PATTERN | ISOSCELES TRIANGLE |
CTHF | CONTACT LOAD CURRENT RATING | 3.2 AMPERES INDUCTIVE LOAD FOURTH VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 4.8 AMPERES INDUCTIVE LOAD SIXTH VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE AND DEACTUATION POINT ADJUSTABLE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 DC AT SEA LEVEL FIFTH VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 DC AT SEA LEVEL SIXTH VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 AC AT SEA LEVEL FOURTH VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS |
PRMT | PRECIOUS MATERIAL | SILVER |
NH200 | NH2-222-3436 | NH2-22-3104 | NH20-20-1-425-1 40 |
NH2-222-3264 | NH2-222-3297 | NH2-222-3362 | NH200 |
NH2-222-3362 | NH2 222 3104 | NH2-222-3264 | NH2000016-10 |
NH2-222-3104 | NH2-222-3297 | NH200 | NH2-222-3297 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote