Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-497-1097 Item Description: Circuit Breaker | 5925 | 014971097 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
462-7068566-95 | 5 | 1 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
ADAQ | BODY LENGTH | 1.562 INCHES MAXIMUM |
TTQY | TERMINAL TYPE AND QUANTITY | 2 SCREW |
THSD | THREAD SERIES DESIGNATOR | UNEF |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | CORROSION RESISTANT AND FUNGUS RESISTANT AND HERMETICALLY SEALED |
ABXD | BUSHING LENGTH | 0.332 INCHES MINIMUM AND 0.380 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 1 |
SR-1 | SPEC/STD CONTROLLING DATA | |
FREQ | FREQUENCY IN HERTZ | 60.0 OR 400.0 SINGLE LOCATION |
ADAT | BODY WIDTH | 0.625 INCHES MAXIMUM |
SR-1 | DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | M39019/02-263S |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 1.5 AMPERES AC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATION |
AGAV | III END ITEM IDENTIFICATION | WEAPON LAUNCH CONSOL ASSEMBLY FOR LOS ANGELES CLASS SUBMARINE 688 |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.906 INCHES MAXIMUM |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING W/PANEL SEAL |
CQJX | NOMINAL THREAD SIZE | 0.375 INCHES |
SR-1 | MANUFACTURERS CODE | 81349 |
AEGJ | SWITCH CONTACT ARRANGEMENT | SINGLE POLE, SINGLE THROW, NORMALLY CLOSED |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 800.0 SINGLE LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC AND 50.0 DC SINGLE LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
AAQL | BODY STYLE | SINGLE POLE TYPE |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 300.0 AC AND 500.0 DC SINGLE LOCATION |
CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 ALARM |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-C-39019/2 GOVERNMENT SPECIFICATION |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.055 MINIMUM AT 200 PCT AND 0.950 MAXIMUM AT 200 PCT AND 0.240 MAXIMUM AT 400 PCT AND 0.060 MAXIMUM AT 800 PCT SINGLE LOCATION |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 23.0 DEG CELSIUS MINIMUM AND 27.0 DEG CELSIUS MAXIMUM SINGLE LOCATION |
ADTV | CASE MATERIAL | METAL |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.810 INCHES MAXIMUM |
SR-1 | NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MIL-PRF-39014/2 |
CQSM | SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE ONE |
462-001-057 | 462-00 | 462-001-056 | 462 007 003 2 |
462-004 | 462 002 | 462-00 | 462-00 |
462-001 | 462-001 | 462-0020E | 462-0040 |
462-003-011 | 462-0060E | 462-0040E | 462-004 |