5950-01-028-0300 Item Description: Transformer Power | 5950 | 010280300 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
5950-08657 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.812 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.281 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTB | MOUNTING HOLE DIAMETER | 0.187 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.125 INCHES NOMINAL |
ADAT | BODY WIDTH | 2.125 INCHES NOMINAL |
ADAU | BODY HEIGHT | 2.718 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | OPEN |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 1.9 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 270.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 30.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 950.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 117.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 12.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 15.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 190.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 28.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 15 WIRE LEAD |
595-00272 | 595-00103 | 595-00512 | 595-00182 |
595-00051 | 595-0012 | 595-00563 | 595-00821 |
595-00272 | 595-00563 | 595-00165 | 595-00563 |
595-00432 | 595-00820 | 595-00103 | 595-00103 |