5905-01-131-7541 Item Description: Resistor Variable N | 5905 | 011317541 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
9-4773-510-41 | 5 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAPN | SECTION QUANTITY | 1 |
AAQL | BODY STYLE | CYLINDRICAL |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | III OVERALL LENGTH | 0.250 INCHES NOMINAL |
ABJT | TERMINAL LENGTH | 0.180 INCHES MINIMUM |
ABPM | BODY DIAMETER | 0.385 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.250 INCHES NOMINAL |
ADAV | III OVERALL DIAMETER | 0.565 INCHES NOMINAL |
AEFD | ACTUATOR TYPE | FLUSH DRIVE WITH SLOT-HOLE |
AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 190.0 NOMINAL |
AEFK | MAXIMUM STARTING TORQUE | 6.00 INCH-OUNCES |
AEFL | MAXIMUM RUNNING TORQUE | 6.00 INCH-OUNCES |
AEFM | MAXIMUM STOP TORQUE | 12.00 INCH-OUNCES |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.200 INCHES NOMINAL |
AFJN | III FRAGILITY FACTOR | MODERATELY RUGGED |
APXH | TERMINAL LOCATION | RADIALLY POSITIONED OVER LESS THAN HALF THE CIRCUMFERENCE |
AXGY | MOUNTING METHOD | TERMINAL |
CBBL | FEATURES PROVIDED | HUMIDITY PROOF |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 10.0 KILOHMS SINGLE SECTION |
CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 360.0 NOMINAL |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.100 INCHES NOMINAL |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 125.0 SINGLE SECTION |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -100.0 TO 100.0 SINGLE SECTION |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.5 FREE AIR SINGLE SECTION |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -20.0 TO 20.0 SINGLE SECTION |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | STOPS |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 40.0 SINGLE SECTION |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |
9 40 10AS | 9-4-4-4 | 9-40-1250 | 9-40-0151-00 |
9-4-7MT5 | 9 4 090156CA | 9-4-7T5 | 9 4 080103 |
9 4 090156CA | 9-4 080103 | 9 4 7KT5 | 9 40 1500AS |
9-4-2067 | 9-4-7T5 | 9-4-7KT5 | 9-40-0151 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote