Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-01-032-1150 Item Description: Switch Pressure | 5930 | 010321150 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
21MX0A 5A 276 | 5 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | WATERTIGHT |
ABKW | OVERALL HEIGHT | 2.813 INCHES NOMINAL |
ABPM | BODY DIAMETER | 7.000 INCHES NOMINAL |
AJZC | PRESSURE SWITCH TYPE | DIFFERENTIAL |
AXGY | MOUNTING METHOD | INPUT PORT |
CBBL | FEATURES PROVIDED | ELECTRICAL ACCESS PORT |
CMLP | THREAD QUANTITY PER INCH | 18 SINGLE PRESSURE CONNECTION |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CQJX | NOMINAL THREAD SIZE | 0.250 INCHES SINGLE PRESSURE CONNECTION |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, TWO POSITIONS MOMENTARY |
CSCF | TERMINAL TYPE | TAB W/SCREW |
CTHF | CONTACT LOAD CURRENT RATING | 10.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 12.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 250.0 MILLIAMPERES RESISTIVE LOAD THIRD VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 500.0 MILLIAMPERES RESISTIVE LOAD FOURTH VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE, MANUAL RESET AND ACTUATION POINT ADJUSTABLE |
CTYM | CONTACT ADJUSTMENT RANGE | +300.00/+2500.00 ACTUATION POINT POUNDS PER SQUARE INCH GAGE |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT SCREW WITH SCALE |
CTYX | CONTACT STIMULUS RATING | 2200.00 DIFFERENTIAL POINT NOMINAL POUNDS PER SQUARE INCH GAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 120.0 AC AT SEA LEVEL SECOND VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 120.0 DC AT SEA LEVEL FOURTH VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 240.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 240.0 DC AT SEA LEVEL THIRD VOLTAGE |
CTZL | PRESSURE CONNECTOR TYPE | PLAIN, THREADED EXTERNAL SINGLE CONNECTION |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
THSD | THREAD SERIES DESIGNATOR | NPT SINGLE PRESSURE CONNECTION |
21M-141-1 | 21M02 | 21M085 | 21M086 |
21M100P39M | 21M-142-1 | 21M02 | 21M-142-2 |
21M-159 | 21M0088 | 21M-70 | 21M-16D03C3E |
21M-25 | 21M-85-2 | 21M0089 | 21M-85-1 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote