Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6105-01-178-4700 Item Description: Motor Alternating C | 6105 | 011784700 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
2695 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ALTERNATING CURRENT | AAJT | OVERALL HEIGHT5 750 INCHES |
ALTERNATING CURRENT | AAJU | OVERALL LENGTH9 250 INCHES |
ALTERNATING CURRENT | AAJV | OVERALL WIDTH7 250 INCHES |
ALTERNATING CURRENT | ABWV | SHAFT DIAMETER0 625 INCHES NOMINAL SINGLE END |
ALTERNATING CURRENT | ABXQ | FLATTED PORTION LENGTH1 500 INCHES NOMINAL SINGLE END |
ALTERNATING CURRENT | AGRB | FLAT DEPTH0 050 INCHES NOMINAL SINGLE END |
ALTERNATING CURRENT | AKCT | SHAFT ROTATION DIRECTIONCLOCKWISE SINGLE END OR COUNTERCLOCKWISE SINGLE END |
ALTERNATING CURRENT | AKPS | DUTY CYCLECONTINUOUS |
ALTERNATING CURRENT | ANPZ | INCLOSURE FEATUREDRIPPROOF PROTECTED-15 DEG |
ALTERNATING CURRENT | AXCP | WINDING TYPEINDUCTION-SPLIT PHASE |
ALTERNATING CURRENT | AXGY | MOUNTING METHODRESILIENT CRADLE |
ALTERNATING CURRENT | AXHR | MOUNTING FACILITY TYPE AND QUANTITY4 SLOT |
ALTERNATING CURRENT | BFMF | COOLING METHODSELF-VENTILATED |
ALTERNATING CURRENT | BKPB | CURRENT RATING METHODLOAD |
ALTERNATING CURRENT | BKPQ | INCLOSURE SPECIFICATIONNEMA |
ALTERNATING CURRENT | CBBL | FEATURES PROVIDEDTHERMAL PROTECTIVE DEVICE |
ALTERNATING CURRENT | CNMM | FRAME SIZE DESIGNATION48 |
ALTERNATING CURRENT | CNXS | POWER RATING0 500 HORSEPOWER OUTPUT |
ALTERNATING CURRENT | CWCS | LENGTH OF SHAFT FROM HOUSING1 500 INCHES SINGLE END |
ALTERNATING CURRENT | CWDM | SHAFT CENTER TO MOUNTING SURFACE DISTANCE3 000 INCHES SINGLE END |
ALTERNATING CURRENT | CWDT | NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2 750 INCHES |
ALTERNATING CURRENT | CWDY | TEMP RATING40 0 AMBIENT DEG CELSIUS AND 70 0 OPERATING DEG CELSIUS |
ALTERNATING CURRENT | CWFX | ROTOR SPEED RATING IN RPM1725 0 SINGLE FULL LOAD |
ALTERNATING CURRENT | CWFY | NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH4 250 INCHES |
ALTERNATING CURRENT | CWGL | CURRENT RATING IN AMPS8 800 SINGLE INPUT |
ALTERNATING CURRENT | CWGQ | CONNECTION TYPE AND VOLTAGE RATING IN VOLTS115 0 LINE TO NEUTRAL FIRST MULTIPLE INPUT OR 208 0 LINE TO NEUTRAL SECOND MULTIPLE INPUT OR 230 0 LINE TO NEUTRAL THIRD MULTIPLE INPUT |
ALTERNATING CURRENT | CWHZ | SHAFT END CHARACTERISTICA5 SINGLE STYLE SINGLE END |
ALTERNATING CURRENT | FAAZ | PHASESINGLE INPUT |
ALTERNATING CURRENT | FREQ | FREQUENCY IN HERTZ60 0 INPUT |
ALTERNATING CURRENT | TTQY | TERMINAL TYPE AND QUANTITY9 WIRE LEAD |
269-0021-88 | 269-0-100UVDC0-40DB | 269-001 | 269-0004-009 |
269-004 | 269-004 | 269-004 | 269-0-100 |
269-0-100 | 269-0-30 | 269-0-100UVDC0-40DB | 269-0-100 |
269-0-100UVDC0-40DB | 269-002 | 269-001 | 269-0004-009 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote