MRC | Criteria | Characteristic |
---|---|---|
SR-5 | DESIGN CONTROL REFERENCE | 010-875 |
AAYV | DISCHARGE CONNECTION QUANTITY | 1 |
AAYT | INTAKE CONNECTION QUANTITY | 1 |
AAYU | INTAKE CONNECTION TYPE | ROUND FLANGE |
BPRZ | SAFETY DEVICE TYPE | HIGH TEMPERATURE SHUTDOWN SWITCH |
AKDJ | PRIME MOVER TYPE | ELECTRIC MOTOR |
AAYW | DISCHARGE CONNECTION TYPE | SQUARE FLANGE |
CQJY | CURRENT TYPE AND RATING IN AMPS | 89.0 AC |
BDML | CONTROL DEVICE TYPE | AUTOMATIC START-STOP |
AAXP | COOLING SYSTEM DESIGN | MIXED |
AAXG | COMPRESSOR QUANTITY | 1 |
AAXQ | COMPRESSED GAS COOLING MEDIUM | SALT WATER |
CSFH | TEMP RATING PER FUNCTION | 105.0 DEG FAHRENHEIT DISCHARGE AND 33.5 DEG FAHRENHEIT SUCTION |
AAXR | COMPRESSOR COOLING MEDIUM | REFRIGERANT |
AAXS | PRIME MOVER COOLING MEDIUM | AIR |
AAXJ | DUTY CYCLE IN PERCENT | 100 |
AAXK | GAS FOR WHICH DESIGNED | AIR |
AAXX | MOUNTING TYPE | BASE |
AAXL | DISCHARGE FLOW RATE | NOT RATED |
AAXM | DISCHARGE PRESSURE | 126.600 POUNDS PER SQUARE INCH GAGE |
CSBH | VOLTAGE IN VOLTS AND CURRENT TYPE | 440.0 AC |
AAYC | CENTRIFUGAL COMPRESSOR DESIGN | RADIAL FLOW |
SR-5 | THE MANUFACTURERS DATA | |
AAYD | STAGE QUANTITY | 2 |
AAYS | COMPRESSOR SPEED AT RATED CAPACITY IN RPM | 1750.0 |
SR-5 | MANUFACTURERS CODE | 12570 |