MRC | Criteria | Characteristic |
---|---|---|
AKDJ | PRIME MOVER TYPE | ELECTRIC MOTOR |
ZZZY | REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | AS DIFFERENTIATED BY RELIANCE ELECTRIC CO MOTOR,DWG NO. 85812 |
AAYT | INTAKE CONNECTION QUANTITY | 1 |
ACDC | CURRENT TYPE | AC |
SR-5 | MANUFACTURERS CODE | 07524 |
ELEC | VOLTAGE IN VOLTS | 440.0 |
AAYU | INTAKE CONNECTION TYPE | ROUND FLANGE |
AHZA | PUMPING ELEMENT OPERATING POSITION | VERTICAL |
AAYV | DISCHARGE CONNECTION QUANTITY | 1 |
SR-5 | DESIGN CONTROL REFERENCE | E3955 |
AMPS | CURRENT RATING IN AMPS | 3.3 |
AHYZ | OPERATING SPEED AT RATED CAPACITY | 420.0 REVOLUTIONS PER MINUTE |
AHZR | ROTARY PUMP DESIGN | GEAR |
AHYV | MAXIMUM DISCHARGE FLOW RATE | 25.0 GALLONS PER MINUTE |
AENC | PUMP QUANTITY | 1 |
AENK | COOLING METHOD | SELF VENTILATED |
SR-5 | THE MANUFACTURERS DATA | |
AAXH | PRIME MOVER QUANTITY | 1 |
ADZC | ENVIRONMENTAL PROTECTION | SPLASHTIGHT |
FAAZ | PHASE | THREE |
AAXS | PRIME MOVER COOLING MEDIUM | AIR |
FREQ | FREQUENCY IN HERTZ | 60.0 |
AAXX | MOUNTING TYPE | BASE |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
ACKL | MEDIA FOR WHICH DESIGNED | HYDROCARBON FUELS AND OILS |
AHYW | DISCHARGE PRESSURE | 50.0 POUNDS PER SQUARE INCH GAGE |
AAYW | DISCHARGE CONNECTION TYPE | ROUND FLANGE |