Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-270-4805 Item Description: Switch Pressure | 5930 | 002704805 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | S | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
2222378 | C | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAJD | THREAD CLASS | 2B SINGLE PRESSURE CONNECTION |
AARX | INSIDE DIAMETER | 0.438 INCHES NOMINAL SINGLE CONNECTION |
AASA | THREAD LENGTH | 0.500 INCHES NOMINAL SINGLE PRESSURE CONNECTION |
ABFE | III HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | GENERAL PURPOSE-NEMA TYPE 1 |
ABHP | OVERALL LENGTH | 5.750 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 10.812 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 3.000 INCHES NOMINAL |
ADAQ | BODY LENGTH | 4.875 INCHES NOMINAL |
ADAU | BODY HEIGHT | 10.312 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.375 INCHES NOMINAL |
AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 3.000 INCHES NOMINAL |
AFDT | SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 1.500 INCHES NOMINAL |
AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 4.250 INCHES NOMINAL |
AJZC | PRESSURE SWITCH TYPE | GAGE |
AWTN | OPERATING TEMP RATING | -30.0 DEG FAHRENHEIT MINIMUM AND 580.0 DEG FAHRENHEIT MAXIMUM |
AXGY | MOUNTING METHOD | BRACKET AND UNTHREADED HOLE |
CBBL | FEATURES PROVIDED | ELECTRICAL ACCESS PORT |
CMLP | THREAD QUANTITY PER INCH | 20 SINGLE PRESSURE CONNECTION |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CQJB | PROOF PRESSURE | 3600.00 POUNDS PER SQUARE INCH GAGE |
CQJX | NOMINAL THREAD SIZE | 0.438 INCHES SINGLE PRESSURE CONNECTION |
CQYJ | MOUNTING FACILITY PATTERN | ISOSCELES TRIANGLE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CSCF | TERMINAL TYPE | SCREW |
CTHF | CONTACT LOAD CURRENT RATING | 15.0 AMPERES RESISTIVE LOAD FOURTH VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 15.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 4.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 4.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
CTYM | CONTACT ADJUSTMENT RANGE | +250.00 TO 3000.00 ACTUATION POINT POUNDS PER SQUARE INCH AND +210.00/+2920.00 DEACTUATION POINT POUNDS PER SQUARE INCH |
CTYS | CONTACT ADJUSTMENT TYPE | INTERNAL ACTUATION POINT HEX NUT WITH SCALE AND INTERNAL DEACTUATION POINT HEX NUT WITH SCALE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL SECOND VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 DC AT SEA LEVEL FOURTH VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 DC AT SEA LEVEL THIRD VOLTAGE |
CTZL | PRESSURE CONNECTOR TYPE | PLAIN, THREADED INTERNAL SINGLE CONNECTION |
FEAT | SPECIAL FEATURES | PHOSPHOR BRONZE HOUSING FOR OXYGEN SERVICE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS |
PMLC | III PRECIOUS MATERIAL AND LOCATION | CONTACTS SILVER |
PRMT | PRECIOUS MATERIAL | SILVER |
STYL | III STYLE DESIGNATOR | RECTANGULAR |
THSD | THREAD SERIES DESIGNATOR | UNF SINGLE PRESSURE CONNECTION |