MRC | Criteria | Characteristic |
---|---|---|
BLJC | Ignition Method | ELECTRODE |
AMPS | Current Rating In Amps | 12.0 |
ELEC | Voltage In Volts | 24.0 |
ACDC | Current Type | DC |
CQTY | Fuel Consumption Rate Per Hour | 0.3 GALLONS |
BDXJ | Heating Element Type | COMBUSTION CHAMBER |
CQXD | Heat Delivery Rate | 15000.0 BRITISH THERMAL UNIT |
FUEL | Fuel Type | DF-A ARCTIC DIESEL FUEL OIL AND DF-1 WINTER DIESEL FUEL OIL AND DF-2 REGULAR DIESEL FUEL OIL AND 80/87 OCTANE GASOLINE AND 91/96 OCTANE GASOLINE |
ZZZK | Specification/Standard Data | 81349-MIL-H-52204 GOVERNMENT SPECIFICATION |
HGTH | Height | 12.000 INCHES NOMINAL |
ZZZT | Nondefinitive Spec/Std Data | 3 TYPE |
SFTT | Surface Treatment | PAINT |
NMBR | Quantity | 1 |
AEJZ | Depth | 13.000 INCHES NOMINAL |
CSGC | Fuel Feed Method | INTERNAL PUMP |
AAXX | Mounting Type | HAND CARRY |
ABBA | Air Circulation Device | PROPELLER FAN |
ABBB | Speed Adjustments | SINGLE SPEED |
ABBD | Maximum Air Flow Rate | 115.0 CUBIC FEET PER MINUTE |
ABAM | Heat Medium Type | AIR |
ABBE | Circulated Air Type | HEATED |
ABFG | Radio Interference Suppression Type | ARMY, MIL-E-53301, RADIO SUPPRESSION |
ABFH | Flue Connection Location | ON LOWER RIGHT REAR 2.750 IN. FROM BOTTOM |
CQSJ | Inclosure Material | STEEL |
AKDJ | Prime Mover Type | ELECTRIC MOTOR |
ABGL | Width | 12.000 INCHES NOMINAL |