Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-898-0500 Item Description: Switch Rotary | 5930 | 008980500 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
429659 | 5 | 8 | E |
MRC | Criteria | Characteristic |
---|---|---|
AAJD | THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
AASA | THREAD LENGTH | 0.560 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AATB | WIDTH BETWEEN FLATS | 0.217 INCHES NOMINAL SINGLE ACTUATOR |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | WATERPROOF |
ABHP | OVERALL LENGTH | 3.390 INCHES MINIMUM AND 3.520 INCHES MAXIMUM |
ABNB | FIRST FLAT LENGTH | 0.370 INCHES NOMINAL SINGLE ACTUATOR |
ABWV | SHAFT DIAMETER | 0.314 INCHES NOMINAL SINGLE ACTUATOR |
ABXF | SHAFT LENGTH | 0.375 INCHES NOMINAL SINGLE ACTUATOR |
ADAV | OVERALL DIAMETER | 1.750 INCHES NOMINAL |
AEFP | NONTURN DEVICE RADIUS | 0.625 INCHES NOMINAL AT 3:00 O'CLOCK |
AFBH | INDIVIDUAL SECTION QUANTITY | 1 |
AFDC | NONTURN DEVICE TYPE | PIN AT 3:00 O'CLOCK |
AJZE | SWITCH CONTACT BASIC DESIGN | NONPILE-UP NONSYMMETRICAL |
AXGY | MOUNTING METHOD | THREADED BUSHING SINGLE MOUNTING FACILITY |
CQJX | NOMINAL THREAD SIZE | 0.500 INCHES SINGLE MOUNTING FACILITY |
CQMK | CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL |
CRJH | SWITCH ACTUATOR INDEXING POSITION QUANTITY | 2 SINGLE ACTUATOR |
CRSJ | SHAFT TYPE | ROUND, PARALLEL FLATTED SINGLE ACTUATOR |
CSCF | TERMINAL TYPE | PIN |
CSLC | SWITCH ACTUATOR POSITIONING INCREMENT | 45.0 DEGREES SINGLE ACTUATOR |
CTDN | SWITCH ACTUATOR STOP DEVICE TYPE | FIXED STOP SINGLE ACTUATOR |
CTHF | CONTACT LOAD CURRENT RATING | 10.0 AMPERES RESISTIVE LOAD DC AT SEA LEVEL AND 10.0 AMPERES INDUCTIVE LOAD DC AT SEA LEVEL AND 5.0 AMPERES LAMP LOAD DC AT SEA LEVEL |
STYL | STYLE DESIGNATOR | SNAP OR LINE |
TEST | TEST DATA DOCUMENT | 81349-MIL-S-13623 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTI |
THSD | THREAD SERIES DESIGNATOR | UNF SINGLE MOUNTING FACILITY |
ZZZK | SPECIFICATION/STANDARD DATA | 96906-MS39060 GOVERNMENT STANDARD |
429-001-220 | 429-001-215 | 429-001-136 | 429-001-212 |
429-001-166 | 429-001-010 | 429-001-206 | 429-001-010 |
429-001-166 | 429-001-208 | 429-001-136 | 429-001-214 |
429-000-000L005 | 429-001-148 | 429-001-083 | 429-001-206 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote