Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5915-00-005-6960 Item Description: Filter Band Pass | 5915 | 000056960 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
F13212-4 | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 1.510 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 0.595 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 1.510 INCHES MAXIMUM |
ADAT | BODY WIDTH | 1.120 INCHES MAXIMUM |
AECR | VIBRATION RESISTANCE RANGE IN HERTZ | +10.0/+2000.0 |
AFGA | III OPERATING TEMP RANGE | -20.0 TO 71.0 DEG CELSIUS |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 476.225 SINGLE RADIO INTERFERENCE PULSES PER SECOND |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 476.525 KILOHERTZ 2ND BAND PASS 2ND FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST BAND PASS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND BAND PASS 2ND FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST BAND PASS |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND BAND PASS 2ND FUNCTION |
AHBL | III PRINCIPAL CIRCUITRY TYPE PER FUNCTION | CRYSTAL 2ND BAND PASS 2ND FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | CRYSTAL 1ST BAND PASS 1ST FUNCTION |
AKNA | INCLOSURE TYPE | ENCASED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 7 TERMINAL |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 3.0 1ST BAND PASS |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 3.0 2ND BAND PASS 2ND FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 PIN INPUT 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 PIN GROUND 3RD FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 4 PIN OUTPUT 2ND FUNCTION |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 475.425 KILOHERTZ 1ST BAND PASS 1ST FUNCTION AND 476.20 KILOHERTZ 1ST BAND PASS 1ST FUNCTION AND 476.25 KILOHERTZ 1ST BAND PASS 1ST FUNCTION AND 477.025 KILOHERTZ 1ST BAND PASS 1ST FUNCTION |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 475.725 KILOHERTZ 2ND BAND PASS 2ND FUNCTION AND 476.50 KILOHERTZ 2ND BAND PASS 2ND FUNCTION AND 476.55 KILOHERTZ 2ND BAND PASS 2ND FUNCTION AND 477.325 KILOHERTZ 2ND BAND PASS 2ND FUNCTION |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 476.20 KILOHERTZ 1ST BAND PASS AND 476.25 KILOHERTZ 1ST BAND PASS 1ST FUNCTION |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 476.50 KILOHERTZ 2ND BAND PASS AND 476.55 KILOHERTZ 2ND BAND PASS |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 30.0 MINIMUM 2ND BAND PASS 2ND FUNCTION AND 1.5 MAXIMUM 2ND BAND PASS 2ND FUNCTION AND 1.5 MAXIMUM 2ND BAND PASS 2ND FUNCTION AND 30.0 MINIMUM 2ND BAND PASS 2ND FUNCTION |
CRBC | III DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 30.0 MINIMUM 1ST BAND PASS AND 1.5 MAXIMUM 1ST BAND PASS AND 1.5 MAXIMUM 1ST BAND PASS AND 30.0 MINIMUM 1ST BAND PASS 1ST FUNCTION |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |