Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-581-4889 Item Description: Switch Pressure | 5930 | 005814889 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
6832g1 | 1 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTPROOF |
ABHP | OVERALL LENGTH | 4.125 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 3.000 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 3.625 INCHES NOMINAL |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 3.000 INCHES NOMINAL |
AJZC | PRESSURE SWITCH TYPE | GAGE |
AWTN | OPERATING TEMP RATING | -30.0 DEG FAHRENHEIT MINIMUM AND 160.0 DEG FAHRENHEIT MAXIMUM |
AXGY | MOUNTING METHOD | BRACKET |
CBBL | FEATURES PROVIDED | AUTOMATIC RESET |
CMLP | THREAD QUANTITY PER INCH | 18 SINGLE PRESSURE CONNECTION |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CQJX | NOMINAL THREAD SIZE | 0.250 INCHES SINGLE PRESSURE CONNECTION |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CSCF | TERMINAL TYPE | WIRE LEAD |
CTHF | CONTACT LOAD CURRENT RATING | 20.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE, PRESET |
CTYM | CONTACT ADJUSTMENT RANGE | +0.20/+15.00 ACTUATION POINT POUNDS PER SQUARE INCH |
CTYX | CONTACT STIMULUS RATING | 70.00 DIFFERENTIAL POINT MINIMUM POUNDS PER SQUARE INCH AND 80.00 DIFFERENTIAL POINT MAXIMUM POUNDS PER SQUARE INCH |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 125.0 AC AT SEA LEVEL SINGLE VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
STYL | III STYLE DESIGNATOR | RECTANGULAR |
THSD | THREAD SERIES DESIGNATOR | NPT SINGLE PRESSURE CONNECTION |
683-00004-04 | 683-00002 | 683-00009 | 683-0001-000 |
683-001 | 683-00004 | 683-00015 | 683-00005 |
683-001 | 683-00016 | 683-00008 | 683-00014 |
683-00006 | 683-0001-000 | 683-00019 | 683-0002 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote