Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-00-825-8243 Item Description: Resistor Variable W | 5905 | 008258243 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Cts7417 | 2 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAPN | SECTION QUANTITY | 1 |
ABJT | TERMINAL LENGTH | 0.188 INCHES NOMINAL |
ABWV | SHAFT DIAMETER | 0.090 INCHES NOMINAL |
ABXF | SHAFT LENGTH | 0.062 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.500 INCHES NOMINAL |
ADAT | BODY WIDTH | 0.188 INCHES NOMINAL |
ADAU | BODY HEIGHT | 0.500 INCHES NOMINAL |
AEDX | SHAFT STYLE | ROUND |
AEFD | ACTUATOR TYPE | SINGLE SHAFT |
AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 360.0 NOMINAL |
APXH | TERMINAL LOCATION | LEFT ADJACENT SIDE TWO ROWS |
AXGY | MOUNTING METHOD | TERMINAL |
AYQR | CENTER TO CENTER DISTANCE BETWEEN TERMINAL ROWS | 0.100 INCHES NOMINAL |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 100.000 OHMS SINGLE SECTION |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.100 INCHES NOMINAL |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 120.0 SINGLE SECTION |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 2.5 FREE AIR SINGLE SECTION |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -10.0 TO 10.0 SINGLE SECTION |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | CONTINUOUS MOTION |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 70.0 SINGLE SECTION |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |
AAQL | BODY STYLE | RECTANGULAR |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.200 INCHES NOMINAL |
CBBL | FEATURES PROVIDED | NONMETALLIC SHAFT |
CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 360.0 NOMINAL |
CTS-120RH | CTS 122 19 | CTS 026T220F253B1A1 | CTS-122-SA |
CTS 129A-2 | CTS-116-AR RH | CTS 02400 5300 | CTS 026T220F253B1A1 |
CTS-1100 | CTS-10-TTL | CTS-120LH | CTS-120-AR |
CTS-16 | CTS-020-04 | CTS-01 | CTS 124 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.