5905-00-205-9555 Item Description: Resistor Variable N | 5905 | 002059555 | N | A | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | ||||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
115948 | 3 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAPN | SECTION QUANTITY | 1 |
AAQL | BODY STYLE | RECTANGULAR |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | III OVERALL LENGTH | 0.495 INCHES NOMINAL |
ABJT | TERMINAL LENGTH | 0.135 INCHES NOMINAL |
ABKW | III OVERALL HEIGHT | 0.434 INCHES NOMINAL |
ABMK | III OVERALL WIDTH | 0.290 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.360 INCHES NOMINAL |
ADAT | BODY WIDTH | 0.290 INCHES NOMINAL |
ADAU | BODY HEIGHT | 0.434 INCHES NOMINAL |
AEFD | ACTUATOR TYPE | FLUSH DRIVE WITH SLOT-HOLE |
AEFK | MAXIMUM STARTING TORQUE | 5.00 INCH-OUNCES |
AEFL | MAXIMUM RUNNING TORQUE | 0.10 INCH-OUNCES |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.300 INCHES NOMINAL |
APXH | TERMINAL LOCATION | RIGHT ADJACENT SIDE SINGLE ROW |
AXGY | MOUNTING METHOD | TERMINAL |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 5.0 KILOHMS SINGLE SECTION |
CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 270.0 NOMINAL |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.150 INCHES NOMINAL |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 125.0 SINGLE SECTION |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -250.0 TO 250.0 SINGLE SECTION |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.5 FREE AIR SINGLE SECTION |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -20.0 TO 20.0 SINGLE SECTION |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | STOPS |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 70.0 SINGLE SECTION |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |
115-000025 | 115-000350 | 115-000061 | 115-0000-595 |
115-00015-29 | 115-00013-1 | 115-00-12 | 115-000-406 |
115-0003-005 | 115-00010-1 | 115-00-012 110V | 115 000084 |
115-0003 | 115-0000-595 | 115-0003 | 115-0 |