Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5915-01-161-3275 Item Description: Filter Band Pass | 5915 | 011613275 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
293-1299-011 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 1.760 INCHES NOMINAL |
ADAQ | BODY LENGTH | 1.400 INCHES NOMINAL |
ADAT | BODY WIDTH | 0.480 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0.450 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.050 INCHES NOMINAL |
AFGA | OPERATING TEMP RANGE | -55.0/+90.0 DEG CELSIUS |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 70.0 MEGAHERTZ BLANK |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS BLANK |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS BLANK |
AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED STUD |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 5.0 BLANK |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 PIN INPUT 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 PIN OUTPUT 2ND FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 PIN GROUND 3RD FUNCTION |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 69.87 MEGAHERTZ BLANK AND 69.955 MEGAHERTZ BLANK AND 70.045 MEGAHERTZ BLANK AND 70.13 MEGAHERTZ BLANK |
CQJX | NOMINAL THREAD SIZE | 0.086 INCHES |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 69.955 MEGAHERTZ BLANK AND 70.045 MEGAHERTZ BLANK |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 20.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK AND 3.0 MAXIMUM BLANK AND 20.0 MINIMUM BLANK |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
TEST | TEST DATA DOCUMENT | 13499-293-1299 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRA |
293-0019-000 | 293-0044-00 | 293-0046-1 | 293-0000 |
293-0006 | 293-0046-3 | 293-0046-3 | 293-0000 |
293-001 | 293-0019-000 | 293-0044-00 | 293-0019 |
293-0046-7 | 293-0044-00 | 293-001 | 293 001 |