Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-291-4726 Item Description: Power Supply | 6130 | 012914726 | 0 | N | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
2698-8766 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 13.750 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 4.850 INCHES NOMINAL |
AGAV | END ITEM IDENTIFICATION | DBRITE; E/I NSN 5895012855834 |
AKAE | MAXIMUM OPERATING ALTITUDE RATING | 12000.0 FEET |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 97.7 AC POUNDS PER HOUR DRY SINGLE OPERATING POWER RQMT AND 126.5 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | -15.0 DC VOLTS NOMINAL 4TH POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | -5.0 DC VOLTS NOMINAL 3RD POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 15.0 DC VOLTS NOMINAL 1ST POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 5.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 49.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 61.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | -0.1/+60.0 DEG CELSIUS |
CBBL | FEATURES PROVIDED | REMOTE ERROR SENSING CAPABILITY AND VOLTAGE ADJUSTMENT AND FUSE AND REMOTE PROGRAMMING AND OUTPUT TO CASE ISOLATION |
CWGH | OUTPUT CURRENT RATING | -1.5 DC AMPERES NOMINAL 4TH POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | -30.0 DC AMPERES NOMINAL 3RD POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 1.5 DC AMPERES NOMINAL 1ST POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 30.0 DC AMPERES NOMINAL 2ND POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 4 SINGLE POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP SINGLE POWER OUTPUT |
CWKG | VENTILATION DESIGN TYPE | EXTERNAL BLOWER |
CWWY | POWER SUPPLY EFFICIENCY LINE | 70.0 |
FEAT | SPECIAL FEATURES | REFERENCE DATA: FIG 10, INDEX 29, TI 6410.20, FA 10220, PG 2-31 |
269-004 | 269-001 | 269-0020-00FAD2-1A1S | 269-0-100 |
269-004 | 269-004 | 269-0-100UVDC0-40DB | 269-0-100UVDC0-40DB |
269-0-100UVDC0-40DB | 269-0004-009 | 269-0021-88 | 269-0-30 |
269-002 | 269-001 | 269-0004-009 | 269-0002-006 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote