Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-430-6282 Item Description: Transformer Power | 5950 | 004306282 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
1010044d | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.812 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.812 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTD | MOUNTING SLOT WIDTH | 0.188 INCHES NOMINAL SINGLE GROUP0.188 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT60.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.000 INCHES NOMINAL3.000 INCHES NOMINAL |
ADAT | BODY WIDTH | 2.625 INCHES MAXIMUM2.625 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 3.062 INCHES NOMINAL3.062 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | OPENOPEN |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND FLANGE SINGLE GROUP AND SLOT SINGLE GROUPSLOT SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT2 SECONDARY SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 11.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY AND 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY12.40 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY AND 13.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 32.20 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 32.20 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY11.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY AND 12.40 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY AND 13.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 9 WIRE LEAD |