Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-620-5819 Item Description: Transformer Power | 5950 | 006205819 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
F203u | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTD | MOUNTING SLOT WIDTH | 0.188 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 400.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 2.875 INCHES NOMINAL |
ADAT | BODY WIDTH | 2.625 INCHES NOMINAL |
ADAU | BODY HEIGHT | 3.375 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | PARTIALLY INCLOSED, DOUBLE SHELL |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND SLOT SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 4.0 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRMJ | WINDING POWER RATING | 97.2 VOLTS-AMPERES SINGLE COMPONENT ALL SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 10.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 117.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 12.00 AC VOLTS MINIMUM SINGLE COMPONENT ALL SECONDARY AND 29.30 AC VOLTS MAXIMUM SINGLE COMPONENT ALL SECONDARY |
FEAT | SPECIAL FEATURES | FIRST AND SECOND PRIMARY WINDING TAPS USED TO SELECT DIFFERENT SECONDARY VOLTAGES |
TTQY | TERMINAL TYPE AND QUANTITY | 11 TAB, SOLDER LUG |
F20-04-F00 | F20-02-000 | F20-04-F00 | F20-04-M00 |
F20-0064C-02MY | F20-03-F00 | F20-02-M00 | F20-03F-000 |
F20-04-M00 | F20-02F00 | F20-03-000 | F20-04-F00 |
F20-04-FM0 | F20-04-FM0 | F20-043 | F20-055-C2 |