Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5999-00-454-5325 Item Description: Delay Line | 5999 | 004545325 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
D1634 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | RECTANGULAR, FRONT CONNECTION |
AAUB | HOLE DIAMETER | 0.115 INCHES MINIMUM AND 0.135 INCHES MAXIMUM |
ABFY | OVERALL DEPTH | 1.114 INCHES NOMINAL |
ADAQ | BODY LENGTH | 5.875 INCHES NOMINAL |
ADAT | BODY WIDTH | 1.328 INCHES NOMINAL |
AFBH | INDIVIDUAL SECTION QUANTITY | 1 |
AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 5.318 INCHES MINIMUM AND 5.338 INCHES MAXIMUM |
AFGA | OPERATING TEMP RANGE | -40.0 TO 175.0 DEG FAHRENHEIT |
AKPV | MOUNTING FACILITY QUANTITY | 2 |
ANNQ | MATERIAL AND LOCATION | ANY ACCEPTABLE OVERALL |
ANSL | INPUT IMPEDANCE RATING | 100.000 OHMS |
ARBR | BODY DEPTH | 0.926 INCHES NOMINAL |
AZGM | MOUNTING FACILITY | UNTHREADED HOLE |
BBBW | MOUNTING PROVISION ARRANGEMENT STYLE | 2 POSITION IN-LINE |
BHTH | ATTENUATION IN DECIBELS | 2.000 |
BZWM | SIGNAL DELAY METHOD | ELECTROMECHANICAL |
CCDN | DELAY TIME VARIATION METHOD | TAPPED |
CCDQ | SECTION DELAY TIME | 1.620 MICROSECONDS MINIMUM SINGLE SECTION |
CCDQ | SECTION DELAY TIME | 1.980 MICROSECONDS MAXIMUM SINGLE SECTION |
CCDR | SEGMENT QUANTITY PER SECTION | 26 SINGLE SECTION |
CCDS | SEGMENT DELAY TIME | 1.215 MICROSECONDS MINIMUM SINGLE SECTION 21ST SEGMENT |
CCDS | SEGMENT DELAY TIME | 1.237 MICROSECONDS MINIMUM SINGLE SECTION 22ND SEGMENT |
CCDS | SEGMENT DELAY TIME | 1.260 MICROSECONDS MINIMUM SINGLE SECTION 23RD SEGMENT |
CCDS | SEGMENT DELAY TIME | 1.283 MICROSECONDS MINIMUM SINGLE SECTION 24TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 1.305 MICROSECONDS MINIMUM SINGLE SECTION 25TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 1.485 MICROSECONDS MAXIMUM SINGLE SECTION 21ST SEGMENT |
CCDS | SEGMENT DELAY TIME | 1.512 MICROSECONDS MAXIMUM SINGLE SECTION 22ND SEGMENT |
CCDS | SEGMENT DELAY TIME | 1.540 MICROSECONDS MAXIMUM SINGLE SECTION 23RD SEGMENT |
CCDS | SEGMENT DELAY TIME | 1.567 MICROSECONDS MAXIMUM SINGLE SECTION 24TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 1.595 MICROSECONDS MAXIMUM SINGLE SECTION 25TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 1.620 MICROSECONDS MINIMUM SINGLE SECTION 26TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 1.980 MICROSECONDS MAXIMUM SINGLE SECTION 26TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 110.000 NANOSECONDS MAXIMUM SINGLE SECTION 2ND SEGMENT |
CCDS | SEGMENT DELAY TIME | 135.000 NANOSECONDS MINIMUM SINGLE SECTION 3RD SEGMENT |
CCDS | SEGMENT DELAY TIME | 165.000 NANOSECONDS MAXIMUM SINGLE SECTION 3RD SEGMENT |
CCDS | SEGMENT DELAY TIME | 180.000 NANOSECONDS MINIMUM SINGLE SECTION 4TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 220.000 NANOSECONDS MAXIMUM SINGLE SECTION 4TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 225.000 NANOSECONDS MINIMUM SINGLE SECTION 5TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 270.000 NANOSECONDS MINIMUM SINGLE SECTION 6TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 275.000 NANOSECONDS MAXIMUM SINGLE SECTION 5TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 315.000 NANOSECONDS MINIMUM SINGLE SECTION 7TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 330.000 NANOSECONDS MAXIMUM SINGLE SECTION 6TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 360.000 NANOSECONDS MINIMUM SINGLE SECTION 8TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 385.000 NANOSECONDS MAXIMUM SINGLE SECTION 7TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 40.000 NANOSECONDS MINIMUM SINGLE SECTION 1ST SEGMENT |
CCDS | SEGMENT DELAY TIME | 405.000 NANOSECONDS MINIMUM SINGLE SECTION 9TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 440.000 NANOSECONDS MAXIMUM SINGLE SECTION 8TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 450.000 NANOSECONDS MINIMUM SINGLE SECTION 10TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 495.000 NANOSECONDS MAXIMUM SINGLE SECTION 9TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 495.000 NANOSECONDS MINIMUM SINGLE SECTION 11TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 540.000 NANOSECONDS MINIMUM SINGLE SECTION 12TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 550.000 NANOSECONDS MAXIMUM SINGLE SECTION 10TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 585.000 NANOSECONDS MINIMUM SINGLE SECTION 13TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 60.000 NANOSECONDS MAXIMUM SINGLE SECTION 1ST SEGMENT |
CCDS | SEGMENT DELAY TIME | 605.000 NANOSECONDS MAXIMUM SINGLE SECTION 11TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 630.000 NANOSECONDS MINIMUM SINGLE SECTION 14TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 660.000 NANOSECONDS MAXIMUM SINGLE SECTION 12TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 675.000 NANOSECONDS MINIMUM SINGLE SECTION 15TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 715.000 NANOSECONDS MAXIMUM SINGLE SECTION 13TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 720.000 NANOSECONDS MINIMUM SINGLE SECTION 16TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 742.500 NANOSECONDS MINIMUM SINGLE SECTION 17TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 765.000 NANOSECONDS MINIMUM SINGLE SECTION 18TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 770.000 NANOSECONDS MAXIMUM SINGLE SECTION 14TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 787.500 NANOSECONDS MINIMUM SINGLE SECTION 19TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 810.000 NANOSECONDS MINIMUM SINGLE SECTION 20TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 825.000 NANOSECONDS MAXIMUM SINGLE SECTION 15TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 880.000 NANOSECONDS MAXIMUM SINGLE SECTION 16TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 90.000 NANOSECONDS MINIMUM SINGLE SECTION 2ND SEGMENT |
CCDS | SEGMENT DELAY TIME | 907.500 NANOSECONDS MAXIMUM SINGLE SECTION 17TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 935.000 NANOSECONDS MAXIMUM SINGLE SECTION 18TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 962.500 NANOSECONDS MAXIMUM SINGLE SECTION 19TH SEGMENT |
CCDS | SEGMENT DELAY TIME | 990.000 NANOSECONDS MAXIMUM SINGLE SECTION 20TH SEGMENT |
CCDX | PULSE RISE TIME RATING | 100.0 NANOSECONDS |
CCFF | TERMINAL TYPE AND QUANTITY | 26 TAB SOLDER LUG |
TEST | TEST DATA DOCUMENT | 19200-10549172 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRA |
D16 1-1M | D16-111 | D16-0002-230 | D16-111 |
D16-0004-001 | D16-121 | D16-111 | D16 1-1M |
D16-113 | D16-121 | D16 1-1M | D16-111 |
D16-114 | D16-0002-350 | D16-121 | D16-112 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote