Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-274-0654 Item Description: Power Supply | 6130 | 012740654 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Fps-29105-00 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 10.250 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 2.500 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 4.000 INCHES NOMINAL |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | SINGLE 1ST OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 2ND OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 3RD OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 4TH OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 5TH OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 100.0 AC POUNDS PER HOUR WET 5TH OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 117.0 AC POUNDS PER HOUR WET 4TH OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 220.0 AC POUNDS PER HOUR WET 3RD OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 230.0 AC POUNDS PER HOUR WET 2ND OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 240.0 AC POUNDS PER HOUR WET 1ST OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | -12.0 DC VOLTS NOMINAL 3RD POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 12.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 5.0 DC VOLTS NOMINAL 1ST POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 1ST OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 1ST OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 2ND OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 2ND OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 3RD OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 3RD OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 4TH OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 4TH OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 5TH OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 5TH OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | +0.1/+70.0 DEG CELSIUS |
CWGH | OUTPUT CURRENT RATING | 1.0 DC AMPERES NOMINAL 2ND POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 1.0 DC AMPERES NOMINAL 3RD POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 3.0 DC AMPERES NOMINAL 1ST POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 3 1ST POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 3 2ND POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 3 3RD POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | SOLDER LUG 1ST POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | SOLDER LUG 2ND POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | SOLDER LUG 3RD POWER OUTPUT |
FPS-024 | FPS-064-BLK | FPS-187 | FPS-120 |
FPS-008 | FPS-003-6040-CL | FPS-024-1100-BLK | FPS-008-1100-BLK |
FPS-008 | FPS-120 | FPS-187 | FPS-1043A |
FPS-016 | FPS-096-4005-CLR | FPS-004-1100-BLK | FPS 063 CLEAR |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote