Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-130-7093 Item Description: Power Supply | 6130 | 011307093 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
654-00023 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 3.500 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 2.560 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 2.500 INCHES NOMINAL |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 105.0 AC VOLTS MINIMUM SINGLE OPERATING POWER RQMT AND 125.0 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | -12.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 12.0 DC VOLTS NOMINAL 1ST POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 420.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | -20.0/+71.0 DEG CELSIUS |
BGHX | OUTPUT CONTROL QUANTITY | 1 1ST POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 1 2ND POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 1ST POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 2ND POWER OUTPUT |
BHQN | RECTIFICATION METHOD | SINGLE PHASE FULL WAVE CENTER TAP |
CBBL | FEATURES PROVIDED | FILTER |
CWGH | OUTPUT CURRENT RATING | 500.0 DC MAJOR AMPERES 1ST POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 500.0 DC MAJOR AMPERES 2ND POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | FRONT PANEL 1ST POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | FRONT PANEL 2ND POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 1ST POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 2ND POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 1ST POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 2ND POWER OUTPUT |
CWHQ | INPUT CONNECTION TYPE | TERMINAL STRIP SINGLE OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 2 SINGLE OPERATING POWER RQMT |