Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5985-00-484-9474 Item Description: Waveguide Assembly | 5985 | 004849474 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
G128-308-001 | 6 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
AHSF | FLANGE QUANTITY | 6 |
AHSX | FLANGE INSIDE WIDTH | 0.705 INCHES MINIMUM FIFTH FLANGE AND 0.707 INCHES MAXIMUM FIFTH FLANGE |
AHSX | FLANGE INSIDE WIDTH | 0.705 INCHES MINIMUM FIRST FLANGE AND 0.707 INCHES MAXIMUM FIRST FLANGE |
AHSX | FLANGE INSIDE WIDTH | 0.705 INCHES MINIMUM FOURTH FLANGE AND 0.707 INCHES MAXIMUM FOURTH FLANGE |
AHSX | FLANGE INSIDE WIDTH | 0.705 INCHES MINIMUM SECOND FLANGE AND 0.707 INCHES MAXIMUM SECOND FLANGE |
AHSX | FLANGE INSIDE WIDTH | 0.705 INCHES MINIMUM THIRD FLANGE AND 0.707 INCHES MAXIMUM THIRD FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.394 INCHES MINIMUM FIFTH FLANGE AND 0.396 INCHES MAXIMUM FIFTH FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.394 INCHES MINIMUM FIRST FLANGE AND 0.396 INCHES MAXIMUM FIRST FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.394 INCHES MINIMUM FOURTH FLANGE AND 0.396 INCHES MAXIMUM FOURTH FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.394 INCHES MINIMUM SECOND FLANGE AND 0.396 INCHES MAXIMUM SECOND FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.394 INCHES MINIMUM THIRD FLANGE AND 0.396 INCHES MAXIMUM THIRD FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 1.298 INCHES MINIMUM FIFTH FLANGE AND 1.328 INCHES MAXIMUM FIFTH FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 1.298 INCHES MINIMUM FIRST FLANGE AND 1.328 INCHES MAXIMUM FIRST FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 1.298 INCHES MINIMUM FOURTH FLANGE AND 1.328 INCHES MAXIMUM FOURTH FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 1.298 INCHES MINIMUM SECOND FLANGE AND 1.328 INCHES MAXIMUM SECOND FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 1.298 INCHES MINIMUM THIRD FLANGE AND 1.328 INCHES MAXIMUM THIRD FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.298 INCHES MINIMUM FIFTH FLANGE AND 1.328 INCHES MAXIMUM FIFTH FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.298 INCHES MINIMUM FIRST FLANGE AND 1.328 INCHES MAXIMUM FIRST FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.298 INCHES MINIMUM FOURTH FLANGE AND 1.328 INCHES MAXIMUM FOURTH FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.298 INCHES MINIMUM SECOND FLANGE AND 1.328 INCHES MAXIMUM SECOND FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.298 INCHES MINIMUM THIRD FLANGE AND 1.328 INCHES MAXIMUM THIRD FLANGE |
AHTD | FLANGE DEPTH | 0.090 INCHES NOMINAL FIFTH FLANGE |
AHTD | FLANGE DEPTH | 0.298 INCHES MINIMUM FIRST FLANGE AND 0.328 INCHES MAXIMUM FIRST FLANGE |
AHTD | FLANGE DEPTH | 0.298 INCHES MINIMUM FOURTH FLANGE AND 0.328 INCHES MAXIMUM FOURTH FLANGE |
AHTD | FLANGE DEPTH | 0.298 INCHES MINIMUM SECOND FLANGE AND 0.328 INCHES MAXIMUM SECOND FLANGE |
AHTD | FLANGE DEPTH | 0.298 INCHES MINIMUM THIRD FLANGE AND 0.328 INCHES MAXIMUM THIRD FLANGE |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.118 INCHES MINIMUM SIXTH FLANGE ALL CONNECTION FACILITIES AND 0.123 INCHES MAXIMUM SIXTH FLANGE ALL CONNECTION FACILITIES |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.142 INCHES MINIMUM FIFTH FLANGE ALL CONNECTION FACILITIES AND 0.147 INCHES MAXIMUM FIFTH FLANGE ALL CONNECTION FACILITIES |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.144 INCHES MINIMUM FIRST FLANGE ALL CONNECTION FACILITIES AND 0.147 INCHES MAXIMUM FIRST FLANGE ALL CONNECTION FACILITIES |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.144 INCHES MINIMUM FOURTH FLANGE ALL CONNECTION FACILITIES AND 0.147 INCHES MAXIMUM FOURTH FLANGE ALL CONNECTION FACILITIES |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.144 INCHES MINIMUM SECOND FLANGE ALL CONNECTION FACILITIES AND 0.147 INCHES MAXIMUM SECOND FLANGE ALL CONNECTION FACILITIES |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.144 INCHES MINIMUM THIRD FLANGE ALL CONNECTION FACILITIES AND 0.147 INCHES MAXIMUM THIRD FLANGE ALL CONNECTION FACILITIES |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.15 |
AHTX | INSERTION LOSS IN DECIBELS | 0.30 |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 0.699 INCHES MINIMUM AND 0.705 INCHES MAXIMUM |
CRFH | WAVEGUIDE INSIDE WIDTH | 0.620 INCHES MINIMUM AND 0.625 INCHES MAXIMUM |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.309 INCHES MINIMUM AND 0.314 INCHES MAXIMUM |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.388 INCHES MINIMUM AND 0.394 INCHES MAXIMUM |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE ALL FLANGES ALL CONNECTION FACILITIES |
CTCJ | FLANGE STYLE | COVER TYPE FIFTH FLANGE |
CTCJ | FLANGE STYLE | COVER TYPE FIRST FLANGE |
CTCJ | FLANGE STYLE | COVER TYPE FOURTH FLANGE |
CTCJ | FLANGE STYLE | COVER TYPE SECOND FLANGE |
CTCJ | FLANGE STYLE | COVER TYPE THIRD FLANGE |
MATT | MATERIAL | COPPER ALLOY ALL TUBING SEGMENT AND FLANGE |
ZZZV | FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
G12-10205-10 | G12-0480 | G12-0490 | G12-0480 |
G12-100 | G12-0470 | G12-108420-001 | G12 0710 |
G12-0600 | G12-0920 | G12-1 | G12 0750 |
G12-0480 | G12-0770 | G12-10205-11B | G12-0980 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote