MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | W/O MTG FACILITIES, TERMINALS ON OPPOSITE SURFACES |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 2.000 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.400 INCHES NOMINAL |
ADAT | BODY WIDTH | 0.090 INCHES NOMINAL |
ADAU | BODY HEIGHT | 0.180 INCHES NOMINAL |
AEBT | TERMINAL DIAMETER | 0.016 INCHES NOMINAL |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
CQBF | INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP | 100.0 MEGOHMS |
CQBQ | CAPACITANCE VALUE PER SECTION | 10000.000 PICOFARADS SINGLE SECTION |
CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 50.0 DC SINGLE SECTION |
CRTP | TOLERANCE RANGE PER SECTION | -5.00/+5.00 PERCENT SINGLE SECTION |
CWJK | CASE MATERIAL | PLASTIC |
CWPK | INSULATION RESISTANCE AT REFERENCE TEMP | 50000.0 MEGOHMS |
CWPM | DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 0.3000 |
CWSG | TERMINAL SURFACE TREATMENT | SOLDER |
TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
625-0003 | 625-00042 | 625-0005 | 625-00031 |
625-0000 | 625-0007-901 | 625-0003 | 625-0004 |
625-00015 | 625-00042 | 625-001-00424-02 | 625-000-021 |
625-000-022 | 625-00016 | 625-00017 | 625-0007-901 |