5930-01-348-5049 Item Description: Switch Pressure | 5930 | 013485049 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
E1h-H15-P6-Pls | 5 | 1 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | WATERTIGHT |
ABHP | OVERALL LENGTH | 3.190 INCHES NOMINAL |
ABKV | OUTSIDE DIAMETER | 0.125 INCHES NOMINAL SINGLE CONNECTION |
ABMK | OVERALL WIDTH | 2.500 INCHES NOMINAL |
ADAU | BODY HEIGHT | 3.000 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.203 INCHES MINIMUM |
AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 2.440 INCHES NOMINAL |
AGAV | END ITEM IDENTIFICATION | 4610-01-219-8707 WATER PURIFICATION EQUIPMENT SET |
AJZC | PRESSURE SWITCH TYPE | GAGE |
AXGY | MOUNTING METHOD | UNTHREADED HOLE |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CQJX | NOMINAL THREAD SIZE | 0.125 INCHES SINGLE PRESSURE CONNECTION |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION DIAGONAL |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CSCF | TERMINAL TYPE | SCREW |
CTHF | CONTACT LOAD CURRENT RATING | 10.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT SCREW AND EXTERNAL DEACTUATION POINT SCREW |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 120.0 AC AT SEA LEVEL SINGLE VOLTAGE |
CTZL | PRESSURE CONNECTOR TYPE | PLAIN, THREADED EXTERNAL SINGLE CONNECTION |
FREQ | FREQUENCY IN HERTZ | 60.0 SINGLE VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS |
STYL | III STYLE DESIGNATOR | RECTANGULAR |
THSD | THREAD SERIES DESIGNATOR | NPT SINGLE PRESSURE CONNECTION |
ABKW | OVERALL HEIGHT | 5.250 INCHES NOMINAL |
CQJB | PROOF PRESSURE | 400.00 POUNDS PER SQUARE INCH GAGE |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE AND DEACTUATION POINT ADJUSTABLE |
AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 2.620 INCHES NOMINAL |
AWTN | OPERATING TEMP RATING | -20.0 DEG FAHRENHEIT MINIMUM AND 165.0 DEG FAHRENHEIT MAXIMUM |
CTYM | CONTACT ADJUSTMENT RANGE | +0.60/+15.00 ACTUATION POINT POUNDS PER SQUARE INCH GAGE AND +0.50/+14.20 DEACTUATION POINT POUNDS PER SQUARE INCH GAGE |