MRC | Criteria | Characteristic |
---|---|---|
CYDV | PUMP DESIGN CONTROL ACTIVITY | 10941 |
AGAV | III END ITEM IDENTIFICATION | WEAPON SYSTEM CODE JK, WASP CLASS LHD, CARVER PUMP CO, 7N CLOSED COUPLED DEMINERALIZED WATER COOLING PUMP |
CYDW | PUMP MODEL NUMBER FOR WHICH DESIGNED | 7N-3500-25 |
MATT | MATERIAL | IRON ALLOY |
BGRY | CONNECTION LOCATION | INLET CONNECTION |
FEAT | SPECIAL FEATURES | MATL ACI-CN-7M, ASTM A743, GR CN-7M, IRON-CHROMIUM W HEAT TREATMENT REQUIREMENTS; SUCTION HOUSING; FLANGE PORT 0.563IN.DIA THRU 1.00DIA SPOTFACE ON OPP SIDE, 6 HOLES ON 4.438IN.DIA BC; MTG FLANGE 11.750IN.DIA, 0.438IN.DIA THRU 8 HOLES ON 10.625IN.BC; INTERNAL BORE STEPPED FROM 2.25IN.DIA TO 4.000IN.DIA; O/A 3.375IN.W |
BXPJ | CONNECTION SIZE | 5.563 INCHES |
AWLS | CONNECTION TYPE | FLANGE |