Note : We Will Not Share Your Information To Any Third Parties.
MRC | Criteria | Characteristic |
---|---|---|
AHZV | (NON-CORE DATA) SUBMERSIBILITY | NONSUBMERSIBLE |
AAYT | INTAKE CONNECTION QUANTITY | 1 |
AAYU | INTAKE CONNECTION TYPE | ROUND FLANGE |
AHZA | PUMPING ELEMENT OPERATING POSITION | HORIZONTAL |
AAYV | DISCHARGE CONNECTION QUANTITY | 1 |
ACDC | CURRENT TYPE | AC |
ELEC | VOLTAGE IN VOLTS | 440.0 |
AENK | COOLING METHOD | AIR TO AIR COOLED |
SR-5 | DESIGN CONTROL REFERENCE | D-ETN-0-98-003 |
AFJK | III CUBIC MEASURE | 6.0000 CUBIC FEET |
AGAV | III END ITEM IDENTIFICATION | FORWARD AUXILIARY SEAWATER AIR PUMP USED IN PUMPING AND DRAINAGE SYSTEM ONBOARD 378 FOOT CG VESSELS |
AAYW | DISCHARGE CONNECTION TYPE | ROUND FLANGE |
AHZG | CENTRIFUGAL PUMP IMPELLER SUCTION TYPE | SINGLE |
AHYZ | OPERATING SPEED AT RATED CAPACITY | 1790.0 REVOLUTIONS PER MINUTE |
ADZC | ENVIRONMENTAL PROTECTION | DRIPPROOF |
AMPS | CURRENT RATING IN AMPS | 22.0 |
AHYV | MAXIMUM DISCHARGE FLOW RATE | 250.0 GALLONS PER MINUTE |
AENC | PUMP QUANTITY | 1 |
FAAZ | PHASE | THREE |
AAXS | PRIME MOVER COOLING MEDIUM | AIR |
AHZE | CENTRIFUGAL PUMP DESIGN | MIXED FLOW |
AHYX | TOTAL HEAD | 92.360 FEET |
FREQ | FREQUENCY IN HERTZ | 60.0 |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AAXH | PRIME MOVER QUANTITY | 1 |
CSYL | PRIME MOVER POWER RATING | 15.0 HORSEPOWER |
AHZF | CENTRIFUGAL PUMP IMPELLER QUANTITY | 1 |
SR-5 | THE MANUFACTURERS DATA | |
AKDJ | PRIME MOVER TYPE | ELECTRIC MOTOR |
AAYD | STAGE QUANTITY | 1 |
SR-5 | MANUFACTURERS CODE | 10941 |