Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6145-01-383-8751 Item Description: Cable Power Electri | 6145 | 013838751 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
411804 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
CXCW | CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
CXFK | VOLTAGE RATING | 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS |
SFTT | SURFACE TREATMENT | TIN CORE CONDUCTOR ALL CONDUCTORS TIN 2ND POSITION SHIELD BRAID, METALLIC FIRST CONDUCTOR TIN 2ND POSITION SHIELD BRAID, METALLIC SECOND CONDUCTOR TIN 5TH POSITION SHIELD BRAID, METALLIC CABLE |
ABJH | TEMP RATING | 150.0 DEG CELSIUS |
AMQN | CONDUCTOR QUANTITY | 4 |
BLNZ | STRAND QUANTITY PER CONDUCTOR | 19 ALL CONDUCTORS |
CXDQ | CONDUCTOR ARRANGEMENT AND QUANTITY | 4 SINGLES |
AAGR | CROSS-SECTIONAL SHAPE STYLE | ROUND |
CXDC | ROUND CONDUCTOR SIZE | 18 AWG ALL CONDUCTORS |
ADVL | CROSS SECTION OUTSIDE DIAMETER | 0.253 INCHES NOMINAL |
CXDG | STRAND AWG SIZE PER CONDUCTOR | 30 ALL CONDUCTORS |
MATT | MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORS PLASTIC ETHYLENE-TETRAFLUOROETHYLENE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS COPPER 2ND POSITION SHIELD BRAID, METALLIC FIRST CONDUCTOR COPPER 2ND POSITION SHIELD BRAID, METALLIC SECOND CONDUCTOR PLASTIC ETHYLENE-TETRAFLUOROETHYLENE 4TH POSITION JACKET SECOND CONDUCTOR PLASTIC ETHYLENE-TETRAFLUOROETHYLENE 5TH POSITION JACKET FIRST CONDUCTOR COPPER 5TH POSITION SHIELD BRAID, METALLIC CABLE PLASTIC FLUORINATED ETHYLENE PROPYLENE 6TH POSITION JACKET CABLE |
STDC | SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | ASTM B33 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
HUES | COLOR | ORANGE 1ST POSITION PRIMARY INSULATION FIRST CONDUCTOR RED 1ST POSITION PRIMARY INSULATION SECOND CONDUCTOR WHITE 1ST POSITION PRIMARY INSULATION THIRD CONDUCTOR BLUE 1ST POSITION PRIMARY INSULATION FOURTH CONDUCTOR WHITE 3RD POSITION JACKET FIRST CONDUCTOR WHITE 3RD POSITION JACKET SECOND CONDUCTOR WHITE 5TH POSITION JACKET CABLE |