Note : We Will Not Share Your Information To Any Third Parties.
MRC | Criteria | Characteristic |
---|---|---|
FEAT | SPECIAL FEATURES | PERFORM THE FOLLOWING TESTS: PROOF PRESSURE TEST; FUNCTIONAL TEST; POWER-UP BIT; BOS ACTIVATION; ONITATED BIT; OUTPUT OXYGEN CONCENTRATION TEST; FACILITY REQUIREMENTS: 115 VAC,1 PHASE,400 HZ,3 AMPS MAX OR 115 VAC,1 PHASE,60 HZ,10 AMPS MAX OR 28 VDC,2 AMPS MAX; 48.000 IN LG; 24.000 IN. W; 36.000 IN. H ON MAIN CONSOLE/ENCLOSURE AND 16.000 IN. LG; 24.000 IN. W; 24.000 H ON THE LEAK TEST CONSOLE/ENCLOSURE; MATERIAL: STEEL,ALUMINUM; FINISH: GRAY PAINT; WEIGHT 150 LBS |
SR-5 | MANUFACTURERS CODE | 99251 |
RDAL | III REFERENCE DATA AND LITERATURE | SERD NO. 47052, SERD NO. 8419, T.O. 33C2-10-75-1 |
SR-5 | DESIGN CONTROL REFERENCE | 3301270-6101 |
SR-5 | THE MANUFACTURERS DATA | |
FTLD | III FUNCTIONAL DESCRIPTION | TEST SET,OXYGEN CONCENTRATOR;USED ON THE MOLECULAR SIEVE OXYGEN GENERATING SYSTEM CRU-73/A AND CRU-98/A |
SUPP | III SUPPLEMENTARY FEATURES | COMPANY ITEM NAME-MSOGS CONCENTRATOR TEST STAND |
AGAV | III END ITEM IDENTIFICATION | MULTI-APPLICATION ON THE F-15E AND F-16 ACFT |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |