NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-01-032-4392 Item Description: Resistor Fixed Wire | 5905 | 010324392 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Sp1189-15 | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAPP | ELECTRICAL RESISTANCE | 0.050 OHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -10.000 TO 10.000 |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 125.0 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 150.0 |
AAQZ | INCLOSURE METHOD | ENCAPSULATED |
AARB | TERMINAL TYPE | WIRE LEAD |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 0.500 INCHES MINIMUM |
ABPM | BODY DIAMETER | 0.157 INCHES MINIMUM AND 0.219 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.531 INCHES MINIMUM AND 0.593 INCHES MAXIMUM |
AEFB | POWER DISSIPATION RATING IN WATTS | 3.000 FREE AIR |
STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END |
TEST | TEST DATA DOCUMENT | 13973-860762 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI |
SP1-2L-C | SP1-20 | SP1-1802-2 | SP1-2-3-1437602-5 |
SP1-158-2A | SP1-2-0L-Q | SP1-20 | SP1 1 |
SP1-350-12 | SP1-20L | SP1-10-01 | SP1-158-2A |
SP1-14-01 | SP1-3-C | SP1-3-01 | SP1-2-C |