Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5910-00-833-4406 Item Description: CAPACITOR,FIXED,PAPER DIELECTRIC | 5910 | 008334406 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
CP53B1EF254V | 3 | 2 | 2 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | W/MTG TABS/FLANGES, TERMINAL(S) ON ONE SURFACE |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 0.750 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 1.812 INCHES NOMINAL |
ADAT | BODY WIDTH | 1.000 INCHES NOMINAL |
ADAU | BODY HEIGHT | 1.000 INCHES NOMINAL |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.062 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.188 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.125 INCHES NOMINAL |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
AFHW | III INTERNAL ELECTRICAL CONNECTION TYPE | INSERTED TAB |
BWGP | III SECTION QUANTITY | 2 |
CBBL | FEATURES PROVIDED | MOUNTING HARDWARE |
CQBF | III INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP | 20.0 MEGOHM-MICROFARADS |
CQBQ | III CAPACITANCE VALUE PER SECTION | 0.250 MICROFARADS ALL SECTIONS |
CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 600.0 DC ALL SECTIONS |
CRTP | TOLERANCE RANGE PER SECTION | -10.00 TO 20.00 PERCENT ALL SECTIONS |
CWJK | CASE MATERIAL | METAL |
CWSG | III TERMINAL SURFACE TREATMENT | SOLDER |
TEST | TEST DATA DOCUMENT | 81349-MIL-C-25 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING |
TTQY | TERMINAL TYPE AND QUANTITY | 2 TAB, SOLDER LUG |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-C-25/4A GOVERNMENT SPECIFICATION |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED MOUNTING HOLES |
CWPK | INSULATION RESISTANCE AT REFERENCE TEMP | 6000.0 MEGOHMS |
CWPM | DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 1.0000 |