NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-00-781-3147 Item Description: Resistor Variable W | 5905 | 007813147 | 0 | N | B | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | B | U | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
138-192-0001 | 2 | 2 | 1 |
MRC | Criteria | Characteristic |
---|---|---|
AAPN | SECTION QUANTITY | 1 |
AAQL | BODY STYLE | RECTANGULAR |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 0.285 INCHES MINIMUM AND 0.315 INCHES MAXIMUM |
ABWV | SHAFT DIAMETER | 0.090 INCHES NOMINAL |
ABXF | SHAFT LENGTH | 0.040 INCHES NOMINAL |
ADAU | BODY HEIGHT | 0.360 INCHES MINIMUM AND 0.390 INCHES MAXIMUM |
AEDX | SHAFT STYLE | ROUND, SLOTTED |
AEFD | ACTUATOR TYPE | SINGLE SHAFT |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.200 INCHES NOMINAL |
APXH | TERMINAL LOCATION | LOWER ADJACENT SIDE SINGLE ROW |
AXGY | MOUNTING METHOD | TERMINAL |
CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 9000.0 NOMINAL |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.100 INCHES NOMINAL |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 175.0 SINGLE SECTION |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -50.0 TO 50.0 SINGLE SECTION |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -5.0 TO 5.0 SINGLE SECTION |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | CLUTCH |
TEST | TEST DATA DOCUMENT | 95542-138-192 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |
ADAQ | BODY LENGTH | 0.360 INCHES MINIMUM AND 0.390 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0.188 INCHES MINIMUM AND 0.218 INCHES MAXIMUM |
AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 9000.0 NOMINAL |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 5.0 KILOHMS SINGLE SECTION |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 1.0 FREE AIR SINGLE SECTION |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 70.0 SINGLE SECTION |
138-0-0-202 | 138-0002-09 | 138-0002-17 | 138-0-0-202 |
138-0000-001 | 138-0002-07 | 138-0002-15 | 138-0000-001 |
138-0002-18 | 138-0002-16 | 138-0-0-202 | 138-0002-03 |
138-0002-08 | 138-00-22 | 138-0002-12 | 138-0002-02 |