MRC | Criteria | Characteristic |
---|---|---|
AAPN | SECTION QUANTITY | 1 |
AAQL | BODY STYLE | RECTANGULAR W/MOUNTING HOLES |
ABHP | III OVERALL LENGTH | 0.530 INCHES NOMINAL |
ABJT | TERMINAL LENGTH | 0.500 INCHES MINIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.078 INCHES NOMINAL |
ABXF | SHAFT LENGTH | 0.030 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.500 INCHES NOMINAL |
ADAT | BODY WIDTH | 0.220 INCHES NOMINAL |
ADAU | BODY HEIGHT | 0.500 INCHES NOMINAL |
AEFD | ACTUATOR TYPE | SINGLE SHAFT |
AEFK | MAXIMUM STARTING TORQUE | 5.00 INCH-OUNCES |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.200 INCHES NOMINAL |
AXGY | MOUNTING METHOD | UNTHREADED HOLE |
CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 9000.0 NOMINAL |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 175.0 SINGLE SECTION |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -30.0 TO 30.0 SINGLE SECTION |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -5.0 TO 5.0 SINGLE SECTION |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | CLUTCH |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKW | III OVERALL HEIGHT | 0.500 INCHES NOMINAL |
ABMK | III OVERALL WIDTH | 0.715 INCHES MINIMUM |
ABWV | SHAFT DIAMETER | 0.083 INCHES NOMINAL |
AEDX | SHAFT STYLE | ROUND, SLOTTED |
AGTP | LATERAL DISTANCE BETWEEN MOUNTING HOLE CENTERS | 0.520 INCHES NOMINAL |
AKPV | MOUNTING FACILITY QUANTITY | 2 |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 2.000 KILOHMS SINGLE SECTION |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.100 INCHES NOMINAL |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 1.0 FREE AIR SINGLE SECTION |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 70.0 SINGLE SECTION |
TEST | TEST DATA DOCUMENT | 95542-138-062 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW |