MRC | Criteria | Characteristic |
---|---|---|
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.75 FREE AIR SINGLE SECTION |
ADAQ | BODY LENGTH | 1.250 INCHES NOMINAL |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 85.0 SINGLE SECTION |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 150.0 SINGLE SECTION |
SR-1 | SPEC/STD CONTROLLING DATA | |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 25.0 KILOHMS SINGLE SECTION |
ADAT | BODY WIDTH | 0.190 INCHES NOMINAL |
ABHP | III OVERALL LENGTH | 1.320 INCHES NOMINAL |
AEDX | SHAFT STYLE | ROUND, SLOTTED |
AKPV | MOUNTING FACILITY QUANTITY | 2 |
ABKW | III OVERALL HEIGHT | 0.815 INCHES NOMINAL |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |
ABTB | MOUNTING HOLE DIAMETER | 0.093 INCHES NOMINAL |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-22097/2 GOVERNMENT SPECIFICATION |
APXH | TERMINAL LOCATION | LOWER ADJACENT SIDE SINGLE ROW |
AXGY | MOUNTING METHOD | UNTHREADED HOLE AND TERMINAL |
AEFD | ACTUATOR TYPE | SINGLE SHAFT |
AGTP | LATERAL DISTANCE BETWEEN MOUNTING HOLE CENTERS | 1.000 INCHES NOMINAL |
ABMK | III OVERALL WIDTH | 0.190 INCHES NOMINAL |
ABWV | SHAFT DIAMETER | 0.115 INCHES NOMINAL |
ABXF | SHAFT LENGTH | 0.070 INCHES NOMINAL |
AAPN | SECTION QUANTITY | 1 |
SR-1 | NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MIL-R-22097/2 |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.700 INCHES NOMINAL |
AAQL | BODY STYLE | RECTANGULAR W/MOUNTING HOLES/SLOTS |
CSDL | STANDARD TAPER CURVE PER SECTION | A SINGLE SECTION |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
SR-1 | DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | RJ12CP253 |
ABJT | TERMINAL LENGTH | 0.500 INCHES NOMINAL |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.300 INCHES NOMINAL |
SR-1 | MANUFACTURERS CODE | 81349 |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -10.0 TO 10.0 SINGLE SECTION |
ADAU | BODY HEIGHT | 0.315 INCHES NOMINAL |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -250.0 TO 250.0 SINGLE SECTION |