Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-00-419-9817 Item Description: Resistor Variable W | 5905 | 004199817 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
3507s-676-103 | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAPN | SECTION QUANTITY | 1 |
AAQL | BODY STYLE | CYLINDRICAL BUSHING MOUNTED |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 2.690 INCHES NOMINAL |
ABNB | FIRST FLAT LENGTH | 0.375 INCHES NOMINAL |
ABNC | FLAT HEIGHT | 0.216 INCHES NOMINAL |
ABPM | BODY DIAMETER | 1.000 INCHES NOMINAL |
ABWV | SHAFT DIAMETER | 0.250 INCHES NOMINAL |
ABXF | SHAFT LENGTH | 0.800 INCHES NOMINAL |
ADAP | MOUNTING BUSHING LENGTH | 0.250 INCHES NOMINAL |
ADAQ | BODY LENGTH | 1.640 INCHES NOMINAL |
ADAV | OVERALL DIAMETER | 1.000 INCHES NOMINAL |
AEDX | SHAFT STYLE | ROUND, FLATTED |
AEFD | ACTUATOR TYPE | SINGLE SHAFT |
AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 3600.0 NOMINAL |
AEFK | MAXIMUM STARTING TORQUE | 4.00 INCH-OUNCES |
AEFL | MAXIMUM RUNNING TORQUE | 4.00 INCH-OUNCES |
AEFM | MAXIMUM STOP TORQUE | 48.00 INCH-OUNCES |
AJYN | SCREW THREAD DIAMETER | 0.375 INCHES NOMINAL |
AJYP | SCREW THREAD SERIES DESIGNATOR | UNEF |
AJYQ | SCREW THREAD QUANTITY PER INCH | 32.0 |
APXH | TERMINAL LOCATION | REAR END |
AXGY | MOUNTING METHOD | STANDARD BUSHING |
CBBL | FEATURES PROVIDED | NONMETALLIC SHAFT |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 10.0 KILOHMS SINGLE SECTION |
CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 3600.0 NOMINAL |
CQFL | FUNCTION CONFORMITY TOLERANCE PER SECTION | -0.50/+0.50 SINGLE SECTION |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 100.0 SINGLE SECTION |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 1.0 FREE AIR SINGLE SECTION |
CRGM | FUNCTION CONFORMITY PER SECTION | SINGLE SECTION INDEPENDENT LINEARITY |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -10.0/+10.0 SINGLE SECTION |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | STOPS |
CSBX | FUNCTION CHARACTERISTIC PER SECTION | SINGLE SECTION LINEAR |
CSCY | TEMP COEFFICIENT OF RESISTANCE WIRE PER SECTION IN PPM PER DEG CELSIUS | -20.0/+20.0 SINGLE SECTION |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 40.0 SINGLE SECTION |
TEST | TEST DATA DOCUMENT | 18876-10163373 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRA |
TTQY | TERMINAL TYPE AND QUANTITY | 3 WIRE LOOP |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote