Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-01-144-2865 Item Description: Resistor Variable N | 5905 | 011442865 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
806910 | C | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAPN | SECTION QUANTITY | 1 |
AAQL | BODY STYLE | RECTANGULAR |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | III OVERALL LENGTH | 0.430 INCHES MINIMUM |
ABJT | TERMINAL LENGTH | 0.200 INCHES MINIMUM |
ABKW | III OVERALL HEIGHT | 0.390 INCHES NOMINAL |
ABMK | III OVERALL WIDTH | 0.360 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.240 INCHES NOMINAL |
ADAT | BODY WIDTH | 0.360 INCHES NOMINAL |
ADAU | BODY HEIGHT | 0.390 INCHES NOMINAL |
AEFD | ACTUATOR TYPE | FLUSH DRIVE WITH SLOT-HOLE |
AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 280.0 NOMINAL |
AEFK | MAXIMUM STARTING TORQUE | 5.00 INCH-OUNCES |
AEFL | MAXIMUM RUNNING TORQUE | 5.00 INCH-OUNCES |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.200 INCHES NOMINAL |
AFJN | III FRAGILITY FACTOR | MODERATELY RUGGED |
APXH | TERMINAL LOCATION | REAR END |
AXGY | MOUNTING METHOD | TERMINAL |
CBBL | FEATURES PROVIDED | HUMIDITY PROOF |
CBME | III CUBIC MEASURE | 0.034 CUBIC INCHES |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 2.000 KILOHMS SINGLE SECTION |
CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 310.0 NOMINAL |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.100 INCHES NOMINAL |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 125.0 SINGLE SECTION |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -150.0 TO 150.0 SINGLE SECTION |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.5 FREE AIR SINGLE SECTION |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -20.0 TO 20.0 SINGLE SECTION |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | STOPS |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 70.0 SINGLE SECTION |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |
806-005 | 806-000X5U0-102P | 806-005 CPVC | 806-0002 |
806-005 CPVC | 806-0011-01-00 | 806-005 | 806-005PVC |
806-000X5U0-102P | 806-005PVC | 806-005 | 806-0047 |
806-0027 | 806-005 CPVC | 806-000X5E0-821K | 806-0009 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote